Opening Of The Pressure Chamber - Dreve Drufosmart scan Instrucciones De Trabajo

Termoadaptador a presión universal
Ocultar thumbs Ver también para Drufosmart scan:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Drufosmart scan
Info
For safety reasons the quartz
radiator is equipped with a final
switch and only works in swivelled
in position after having started a
programme.
If the quartz radiator is swivelled
outwards after having started a
programme, the heating process
will be interrupted automatically.
The indication in the display (a) will
stop and show the remaining time.
By swivelling the quartz radiator
back in the programme will be re-
activated.
8.4 Thermoforming
After the heating time has elapsed
there will be an acoustic signal; the
heating time in the display will be
00:00. The heating will be switched
off automatically. Pull the heating (4)
at the handle (5) away from the centre
of the unit as far as it will go with the
right hand.
Then push the activation lever (34) with
the left hand downwards as far as it will
go. By pulling the heating handle (5)
again as far as it will go the pressure
chamber closes completely and pres-
surising of the piston will be carried out
automatically. This is confirmed by an
acoustic signal.
34
Attention! The swivelling housing
of the heating element reaches high
temperatures. Therefore it must not
be touched – even not for short
moments.
After the adjusted time has elapsed
the indicator (a) in the display will
stop and count the duration after
termination of the heating time.
This process may be stopped by
successive thermo-forming.
Info
For safety reasons the pressure
chamber can only be pressurised, if
it has been moved downwards com-
pletely manually. In order to protect
the operating personnel securely
against bruises of the fingers, pres-
surising can only be effected, if the
unit is operated with two hands at
the same time (two-hand control).
Always make sure that no objects
are in the contact area between pis-
ton and insert bowl while the piston
is closing!
There will be an automatic pressurising
up to 4 bars. The pressure inside the
pressure chamber will be verified per-
manently by the electronics and regu-
lated, if necessary. The display shows
the given cooling time (c) which then
counts down to 00:00.

8.5 Opening of the pressure chamber

In order to attain a complete cool down
Then swivel the pressure chamber
of the thermoforming blank the valve
into its original position by leading
at the tension ring (12) is to be opened
back the activation lever (34). Swivel
slightly after 2/3 of the adjusted cool-
out the plate reception (11) at the cor-
ing time. Through this the warm air
responding handle (10) and remove
inside the piston will be released and
tension ring and thermoformed result.
replaced by cool air due to the pres-
sure regulation of the electronics. After
The display (2) will show the last used
the cooling time has elapsed there will
programme; the scanning device (1) is
be an acoustic signal (indication in the
ready for a new thermoforming process.
display (c) will blink).
Pull the heating handle (5) again as
far as it will go and maintain it in this
position (approx. 2–3 seconds) until
the pressure is relieved.
35