JUNO IC1ALED NEW CONSTRUCTION RECESSED HOUSINGS
WARNING: For your safety, read and understand instructions completely before starting installation.
Before wiring to power supply, turn off electricity at the fuse or circuit breaker box.
NOTE: Juno recessed fixtures are designed to meet the latest NEC requirements and are listed in full compliance with the relevant UL
standard(s). Before attempting installation of any recessed lighting fixture, check your local electrical building code. This code sets the
wiring standards and installation requirements for your locality and should be understood before starting work. Use of non-Juno trims
voids Juno warranty.
SAVE THESE INSTRUCTIONS
TYPE IC FOR
INSULATED CEILINGS
Figure 1
Juno Type IC fixtures are designed for direct
contact with insulating materials which are
approved for this application (Fig. 1). Fixtures
may also be used in non-insulated ceilings.
Juno Air-Loc LED housings are supplied
with pre-installed gaskets for energy savings
and to comply with energy code air leakage
requirements per ASTM E283.
INSTALLATION INTO
JOIST CONSTRUCTION
Figure 2
Step 1. Extend bar hangers to fit between joists.
Bar hanger foot is contoured to easily align
with bottom of joist (Fig. 2). Position fixture by
hammering Real-Nails
into joists (Fig. 3).
®
(Note: Bar hanger may be shortened to fit 12"
framing or smaller by breaking at score lines).
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • Visit us at www.acuitybrands.com/juno-recessed
©2017 Acuity Brands Lighting, Inc
INSTALLATION INSTRUCTIONS
Step 2. Slide fixture along bar hangers into
desired location. Use locking screws or slot to
secure (Fig. 4).
Relocating Fixture – Nail can be removed
with hammer claw to allow easy repositioning
of fixture without damaging bar hanger or nail
(Fig. 5).
Step 3. Follow steps 1-4 under Electrical
Connection.
Step 4. When installing in drywall, cut a hole
measuring 4-1/2" diameter. After installing
drywall, adjust inner housing height (if
necessary) to match the bottom surface of
ceiling by pulling down on inner housing, which
is retained by springs. The housing is adjustable
for ceilings up to 1-1/2" thick.
Figure 3
Figure 4
Rev 3/17
P3637
INSTALLATION INTO
SUSPENDED CEILING
Step 1. Locate center of proposed opening
on ceiling tile and cut a hole measuring 4-1/2"
diameter.
Step 2. Place ceiling tile in T-bar grid.
Step 3. Place fixture into position and snap
bar hanger foot with integral T-bar notch onto
T-bars (Fig. 6). Additional holes are provided for
securing with wire or screws if desired (Fig. 7).
Step 4. Follow Steps 1-4 under Electrical
Connection.
Figure 5
Figure 6
Figure 7
1 of 2