Descargar Imprimir esta página

Acuity Brands AFFINITY LITHONIA LIGHTING AFF OELR LED Manual Del Usuario

Luz remota

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

AFF OELR LED Remote Light
Installation and wiring.................................................................................................. Page 2-3
Maintenance ..............................................................................................................Page 4-5
Wiring diagram............................................................................................................Page 5
!
WARNING:
FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, SERIOUS INJURY OR
SIGNIFICANT PROPERTY DAMAGE
maintaining this equipment. These instructions do not attempt to cover all installation and maintenance situations. If you do not understand
!
these instructions or additional information is required, contact Lithonia Lighting or your local Lithonia Lighting distributor.
WARNING: RISK OF ELECTRIC SHOCK – NEVER CONNECT TO, DISCONNECT FROM OR SERVICE WHILE EQUIPMENT IS
!
ENERGIZED
.
WARNING:
DO NOT USE ABRASIVE MATERIALS OR SOLVENTS. USE OF THESE SUBSTANCES MAY DAMAGE FIXTURE,
WHICH MAY RESULT IN PERSONAL INJURY.
!
WARNING
Do not exceed fixtures ambient temperature -40°F-122°F (-40°C-50°C). Use of unauthorized input voltage voids
:
!
warranty and UL listing of this product and may present a risk of fire or explosion
WARNING: Do not exceed fixtures ambient temperature -40°F-122°F (-40°C-50°C). Use of unauthorized input voltage
voids warranty and UL listing of this product and may present a risk of fire or explosion.
All servicing should be performed by qualified personnel.
Consult your local building code for approved wiring and installation.
For use Outdoors. Failure to ensure conduit connections are properly protected against water ingress during installation may void warranty.
Do not mount near gas or electric heater.
Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
Do not use this equipment for other than intended use.
AND DELIVER TO OWNER AFTER INSTALLATION
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- For your protection, read and follow these warnings and instructions carefully before installing or
SAVE THESE INSTRUCTIONS
AFFINITY
.
®

Publicidad

loading

Resumen de contenidos para Acuity Brands AFFINITY LITHONIA LIGHTING AFF OELR LED

  • Página 1 ® AFFINITY AFF OELR LED Remote Light Installation and wiring.…………………………………………….…………………...……………...… Page 2-3 Maintenance ………...……………………..…………………………………………………………...…Page 4-5 Wiring diagram….…...……………………..………………………………………………………..…….Page 5 IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, SERIOUS INJURY OR SIGNIFICANT PROPERTY DAMAGE...
  • Página 2 INSTALLATION and WIRING Page 2 Provide each unit with a 8-30V DC power supply for normal lighting. IMPORTANT: PRODUCT DAMAGE WILL OCCUR IF THE RATED INPUT VOLTAGE IS EXCEEDED. NOTE: To meet the minimum illumination requirements of NFPA 101 (current Life Safety Code), the maximum mounting height from ground of WT is 14.6 feet and of FCT is 14.6 feet This unit should be mounted ONLY through a pair of the preformed keyholes onto a 4”...
  • Página 3 INSTALLATION and WIRING Page 3 SURFACE CONDUIT MOUNTING NOTE: to avoid interference with components in the housing, use the most compact wire connectors appropriate to the wire gauge. PREPARING THE UNIT FOR CONDUIT : BRANCH CIRCUIT WIRING : Remove the conduit plug from inside. The unit The wiring compartment is sized for (3) incoming 12 AWG wires is threaded to accept 1/2”...
  • Página 4 MAINTENANCE Page 4 LIGHT ENGINE / LAMP ASSEMBLY REPLACEMENT Open the unit and disconnect all Remove the mounting screws from bracket and remove the lamp connectors from the charger board, assembly and carefully unplug connectors from lamp assembly. remove screws from the plastic Reconnect the connectors to the new lamp, reinstall the lamp assembly cover and charger board and take and ensure that the lamp wires are not pinched.
  • Página 5 MAINTENANCE and WIRING DIAGRAM Page 5 STATUS LED/TEST SWITCH Federal Communications Commission (FCC) Requirements: This device complies with FCC Title 47, Part 15, Subpart B. this BOARD REPLACEMENT : device does not cause harmful interference. After the unit is opened disconnect the connector from Test switch /Status LED board assembly, flex the snap at one side remove Test switch/Status LED board from plastic cover carefully.
  • Página 6 AFFINITY Lampe OELR DEL AFF à distance Installation et câblage.…………………………………….…………………...……………...… Page 7 sur 8 Entretien ……………..………...………………………………………………………………… Pages 9 et 10 Schéma de câblage….…...……………………..………………………………………………. Page 10 MISES EN GARDE IMPORTANTES Lorsque de l’équipement électrique est utilisé, les précautions de sécurité élémentaires suivantes devraient toujours être prises : VEUILLEZ LIRE ET RESPECTER TOUTES LES CONSIGNES DE SÉCURITÉ...
  • Página 7 INSTALLATION et CÂBLAGE Page 7 Fournissez à chaque appareil une alimentation de 8-30 V CC pour éclairage normal. IMPORTANT : SI LA TENSION D’ENTRÉE NOMINALE EST DÉPASSÉE, CELA POURRAIT ENDOMMAGER LE PRODUIT. REMARQUE : REMARQUE: pour respecter les exigences minimales d'éclairage de la norme NFPA 101 (code de sécurité en vigueur), la hauteur maximale de montage depuis "WT"...
  • Página 8 INSTALLATION et CÂBLAGE Page 8 BRANCHEMENT À UN CONDUIT DE SURFACE REMARQUE : Pour éviter les interférences avec les composants du boîtier, utilisez les connecteurs de fils les plus compacts appropriés à la jauge de fil. PRÉPARATION DE L’APPAREIL POUR LE CÂBLAGE DE DÉRIVATION : CONDUIT : Le compartiment de câblage est dimensionné...
  • Página 9 ENTRETIEN Page 9 REMPLACEMENT DE L’ENSEMBLE MOTEUR DU LUMINAIRE OU DE LA LAMPE Ouvrez l’appareil et débranchez Retirez les vis de fixation du support et retirez l’ensemble du luminaire et tous les connecteurs de la carte du débranchez soigneusement le connecteur de l’ensemble de lampe. chargeur, retirez les vis du Reconnectez les connecteurs à...
  • Página 10 SCHÉMA D’ENTRETIEN et de CÂBLAGE Page 10 REMPLACEMENT DE LA CARTE LED Normes de la Commission fédérale des communications (FCC – Federal Communications Commission) : DU COMMUTATEUR D'ESSAI / ÉTAT Cet appareil est conforme à la FCC, titre 47, partie 15, sous- partie B.
  • Página 11 ® AFFINITY Luz remota AFF OELR LED Instalación y cableado…………………..…………..……………………………………………Páginas 12-13 Mantenimiento ……………..………...………………………………………………………………Páginas 14-15 Diagrama de cableado......................Página 15 MEDIDAS DE SEGURIDAD IMPORTANTES Cuando se utilizan aparatos eléctricos, deben tomarse precauciones básicas de seguridad, incluidas las siguientes: LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD ADVERTENCIA: EL INCUMPLIMIENTO DE ESTAS INSTRUCCIONES Y ADVERTENCIAS PUEDE PROVOCAR LA MUERTE, LESIONES GRAVES O DAÑOS IMPORTANTES A LA PROPIEDAD.
  • Página 12 INSTALACIÓN y CABLEADO Página 12 IMPORTANTE: proporcione a cada unidad una fuente de alimentación de 8-30 V CC para una iluminación normal. EL PRODUCTO PUEDE DAÑARSE SI SE EXCEDE EL VOLTAJE DE ENTRADA. NOTA: Para cumplir con los requisitos mínimos de iluminación de NFPA 101 (Código de seguridad de vida actual), la altura máxima de montaje desde el suelo de “WT”...
  • Página 13 INSTALACIÓN y CABLEADO Página 13 MONTAJE DEL CONDUCTO DE SUPERFICIE NOTA: para evitar interferencia con los componentes de la carcasa, use los conectores más compactos apropiados para el calibre de los cables. PREPARE LA UNIDAD PARA EL CONDUCTO: CABLEADO DEL CIRCUITO DERIVADO: Retire el tapón del conducto desde el interior.
  • Página 14 MANTENIMIENTO Página 14 SUSTITUCIÓN DEL MOTOR DE LUZ/MONTAJE DE LA LÁMPARA Abra la unidad y desconecte todos Retire los tornillos de montaje del soporte y retire el montaje de la los conectores de la placa del lámpara; y desenchufe cuidadosamente los conectores del montaje de la cargador, retire los tornillos de la lámpara.
  • Página 15 MANTENIMIENTO y DIAGRAMA DE CABLEADO Página 15 Requisitos de la Comisión Federal de Comunicaciones REEMPLAZO DE LA TARJETA LED DE (FCC): PRUEBA / ESTADO DEL INTERRUPTOR: Este dispositivo cumple con el Título 47 de la FCC, Parte 15, Subparte B. Este dispositivo no causa interferencia dañina. Después de abrir la unidad, desconecte el conector del interruptor de prueba / ensamblaje de la placa de LED de estado, flexione el cierre a un lado y retire el interruptor de...