Rev06 29-10-2019
Figure 5: Second Smart BatteryProtect in between a battery charger or MPPT solar charge controller
and a Li-ion battery
(applicable with VE.Bus BMS or miniBMS)
The second SBP replaces a Cyrix-Li-charge relay (advantages: lower power consumption, alarm relay).
(not applicable if the charger has remote on-off contacts and can be controlled with an interface cable between the BMS and the charger)
Choose program
for this application.
Caution: uncontrolled reverse current will flow through a Smart BatteryProtect if Vout > Vin. Therefore, never use a Smart BatteryProtect for
battery to battery charging.
Figure 6: Application example for a vehicle or boat, with on/off switch between H and L
(applicable with VE.Bus BMS or miniBMS)