• Direct the joint by means of the adjustment and fastening screw and then fasten the casing towards the
subject to be framed.
• Check that there is no power from the mains and insert the power wires and video signal in the casing
through the PG fairleads. Connect the power wire to the IN terminal board respecting the indications
printed on the printed circuits. Connect the video signal connector (*) and connect it to the camera.
Connect the respective connector to the camera if an auto-iris lens is fi tted.
(*): provided with Urmet Domus 1090 cameras.
• Adjust focus as shown in the camera and lens instruction manual. After making the adjustments,
reassemble the casing with care:
− Reconnect the earth wire of the casing/roof assembly.
− Tighten the rear cover fastening screws.
− Tighten the PG fairlead rings.
− Reposition the roof to cover the casing.
Check that the roof is correctly fastened onto the casing (see fi gures below).
allowed position
14
check correct tightness
of the screw
allowed position
optimal position
4. CHARACTERISTICS
External dimensions with roof:..............................................................................................125x110x410mm
External dimensions (casing only):.........................................................................................115x96x355mm
Internal dimensions: .................................................................................................................70x70x300mm
Internal dimensions (with heater circuit): ..................................................................................70x70x230mm
Weight: ....................................................................................................................................................1.4kg
Material:........................................................................................................... extruded die-cast aluminium
Paint: ....................................................................................................................... RAL9002 epoxy powder
Degree of protection: .................................................................................................................................IP55
HEATER
Power: ........................................................................................................................................ 230Vac, 40W
On temperature: ....................................................................................................................... < 14°C +/- 3°C
Off temperature: ....................................................................................................................... > 20°C +/- 3°C
NOTE: PG fairleads can be used to pass through circular section wires with a diameter in the range from 5
to 13mm.
5. PAN AND TILT
DS1090-132A
DS1090-132A
15