Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

globalindustrial.ca
Assembly Instructions
Customer Service
US: 888-628-3466
Variable Speed Exhaust Fan
READ & SAVE THESE INSTRUCTIONS
WARNING
• TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
• This product contains chemicals which are
known to the state of California to cause
birth defects or other reproductive harm.
• This exhaust fan is not for use in explosive
or combustible atmospheres.
• Read and follow all instructions before
operating fan.
• Do not use fan if any part is damaged or missing.
• Do not alter the fan's assembly.
• All electrical connections should be made
by a qualified electrician. Installation
work and electrical wiring must be done
by qualified person(s) following all local
electrical and safety codes in the United
States and Canada, as well as the National
electrical Code (NEC) and the Occupational
Safety and Health Act (OSHA) in the United
States, and the Canadian Electric Code
(CEC) in Canada.
• Use OSHA approved lock-out tag-out
Variable Speed Exhaust Fan_03-23-15.indd 1
Instrucciones de Ensamblaje
Servicio de atención al Cliente
México: 01.800.681.6940
devices on power supply to prevent shock
and/or electrocution.
• When cutting or drilling into wall or ceiling,
do not damage electrical wiring and other
hidden utilities.
• To reduce the risk of fire or electrical
shock, do not expose to water or rain.
• To reduce the risk of fire or electrical
shock, do not use this fan with any solid
state speed control device.
• To reduce the risk of fire or electrical shock,
do not use an extension cord, unit is intended
to be permanently hard wired to properly
rated electrical service outlet (120V 60Hz)
• To reduce the risk of injury to persons,
install fan at least 7 feet (2.1m) above the
floor (8 feet in Canada).
• The fan frame and motor must be
electrically grounded to a suitable electrical
ground, such as a grounded water pipe or
ground wire system.
• This has a single speed motor which is
equipped with a thermo – protector and
will automatically de-energize the fan if it
overheats for any reason.
1
Distribucion Industrial Globales S DE RL DE CF
Directives d'assemblage
Service à la clientèle
Canada: 888-645-2986
MODELS
Fan With
Shutter
248448A - 10"
294495A - 12"
294496A - 18"
294497A - 24"
Fan
246617 - 10"
246618 - 12"
246619 - 18"
246620 - 24"
RULES FOR SAFE OPERATION:
1. Never insert fingers or any other objects
through the grill guard when fan is in
operation.
2. Install in interior wall. Not for use in
kitchens.
3. Disconnect the fan from its power source
when removing guards for cleaning.
4. Do not use the fan in windows. Rain and
moisture may create electrical hazard.
5. Do not place the fan near an open flame,
cooking or heating appliance, or hot
surface.
6. This fan is for indoor dry applications.
7. This fan should not be operated outside.
8. For proper exhaust operation, a window,
door, or louver should be opened on the
opposite side of the area to be ventilated.
9. Periodically clean the propeller, guard,
motor, and louver of any accumulated dirt.
033015
4/2/2015 2:41:55 PM

Publicidad

loading

Resumen de contenidos para Global 248448A

  • Página 1 Service à la clientèle México: 01.800.681.6940 Canada: 888-645-2986 US: 888-628-3466 Variable Speed Exhaust Fan MODELS Fan With Shutter 248448A - 10" 294495A - 12" 294496A - 18" 294497A - 24" 246617 - 10" 246618 - 12" 246619 - 18" 246620 - 24"...
  • Página 2 Mounting hardware is not included. Use appropriate hardware for wall condition. 1/4" x 1/2" Slot Model Size Recommended rough in hole size 248448A 10" 10.5" square hole 294495A 12" 12.5" square hole 294496A 18"...
  • Página 3 1-800-645-2986 Assembly Instructions Variable Speed Exhaust Fan Use appropriate screws for framework and wall conditions. To mount louver assembly, use the eight pre-punched 1/4" x 1/2" slotted mounting holes of the louver assembly to attach the unit to the framework. Seal the joint between the wall and the louver with silicon or any other sealer.
  • Página 4 1-800-645-2986 Assembly Instructions Variable Speed Exhaust Fan Use bolts H1 and washers H2 and vibration pad H3 to assemble motor/ fan-guard to inner fan guard to louver- assembly. Bolt Flat Washer Vibration Pad 4 Pieces 4 Pieces 4 Pieces FAN INSTALLATION INSTRUCTIONS Connect power to the motor, using the appropriate wiring method.
  • Página 5: Ventilador De Extracción De Velocidad Variable

    Service à la clientèle México: 01.800.681.6940 Canada: 888-645-2986 US: 888-628-3466 Ventilador de Extracción de Velocidad Variable MODELOS Ventilador con Persiana 248448A - 10" 294495A - 12" 294496A - 18" 294497A - 24" Ventilador 246617 - 10" 246618 - 12" 246619 - 18"...
  • Página 6 El hardware de montaje no está incluido. Use hardware apropiado según el tipo de pared. 1/4" x 1/2" Ranura Modelo Tamaño Tamaño de agujero recomendado 248448A 10" 10.5" agujero cuadrado 294495A 12" 12.5" agujero cuadrado 294496A 18" 19" agujero cuadrado 294497A 24"...
  • Página 7 01.800.681.6940 Instrucciones de Ensamblaje Ventilador de Extracción de Velocidad Variable Use tornillos apropiados para cada determinado tipo de pared. Para montar la persiana, use las 8 1/4" x 1/2" ranuras de montaje para ensamblar la unidad al marco de la pared.
  • Página 8 01.800.681.6940 Instrucciones de Ensamblaje Ventilador de Extracción de Velocidad Variable Use tornillos H1 y arandelas H2 y almohadilla antivibración H3 para ensamblar el ventilador a la persiana. Tornillo Arandela Almohadilla Plana Antivibración 4 Piezas 4 Piezas 4 Piezas INSTRUCCIONES DE INSTALACIÓN DEL VENTILADOR Blanco Marrón Connecte la alimentación eléctrica al motor usando el cableado de...
  • Página 9 Service à la clientèle México: 01.800.681.6940 Canada: 888-645-2986 US: 888-628-3466 Ventilateur d’extraction à vitesse variable MODÈLES Ventilateur avec volets 248448A - 10" 294495A - 12" 294496A - 18" 294497A - 24" Ventilateur 246617 - 10" 246618 - 12" 246619 - 18"...
  • Página 10 Outils non compris. Utiliser les outils qui conviennent au type de mur. 1/4" x 1/2" Rainure Modèle Taille Dimension préliminaire recommandée 248448A 10 po Trou carré de 10,5 po 294495A 12 po Trou carré de 12,5 po 294496A 18 po Trou carré...
  • Página 11 01.800.681.6940 Directives d'assemblage Ventilateur d’extraction à vitesse variable Utiliser les vis qui conviennent au mur. Fixer la grille d’aération au mur à l’aide des huit fentes de fixation de ¼ po x ½ po de la grille d’aération. Sceller le joint entre le mur et la grille d’aération avec du silicone ou tout autre scellant.
  • Página 12 01.800.681.6940 Directives d'assemblage Ventilateur d’extraction à vitesse variable Utiliser les boulons H1, les rondelles H2 et les rondelles antivibrations H3 pour fixer le moteur/grille de protection, la grille de protection interne et la grille d’aération. Boulon Rondelle Rondelle Plate Antivibrations 4 pièces 4 pièces 4 pièces...

Este manual también es adecuado para: