Descargar Imprimir esta página
Honeywell Z-Wave ZW4103 Guia De Inicio Rapido
Honeywell Z-Wave ZW4103 Guia De Inicio Rapido

Honeywell Z-Wave ZW4103 Guia De Inicio Rapido

Publicidad

Enlaces rápidos

FCC / IC - EN
This device complies with Part 15 of the FCC and Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements, no change to
the antenna or the device is permitted. Any change to the antenna or the device could result in the
device exceeding the RF exposure requirements and void user's authority to operate the device.
FCC /IC - FR
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les
appareils exempts de licence d'Industrie Canada. Son utilisation est sujette aux
deux conditions suivantes : 1) cet appareil ne doit pas occasionner de brouillage
préjudiciable et 2) cet appareil doit accepter toutes les interférences reçues, notamment
les interférences qui peuvent provoquer un fonctionnement non désiré.
REMARQUE DE LA FCC : Le fabricant n'est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées de
ce matériel. De telles modifications peuvent annuler le droit de l'utilisateur à utiliser cet appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites
ont été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable
en milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence
radio et, s'il n'est pas installé et utilisé conformément aux instructions, il peut provoquer un
brouillage préjudiciable aux communications radio. Il n'existe toutefois aucune garantie que
des interférences ne se produiront pas dans une installation donnée. Si cet appareil occasionne
un brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suffit d'allumer et
d'éteindre l'appareil pour déterminer sa responsabilité. Nous encourageons l'utilisateur à
essayer de corriger ces interférences en appliquant une ou plusieurs des mesures suivantes :
— Réorienter ou déplacer l'antenne de réception.
— Augmenter la distance entre l'appareil et le récepteur.
— Brancher l'appareil à une prise secteur différente de celle du récepteur.
— Pour obtenir de l'aide, consulter le revendeur ou un technicien
spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la
FCC concernant l'exposition aux RF, aucune modification apportée à l'antenne
ou au dispositif n'est autorisée. Toute modification apportée à l'antenne ou au
dispositif pourrait faire en sorte que le dispositif dépasse les exigences d'exposition
aux RF et pourrait annuler le droit de l'utilisateur à utiliser ce dispositif.
FCC /IC - ES
Este dispositivo cumple con las especificaciones del apartado 15 de las normas de
la FCC y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio
de Industria de Canadá aplicables a aparatos exentos de licencia. El funcionamiento
está sujeto a las siguientes dos condiciones: (1) este dispositivo no debe provocar
interferencia perjudicial, y (2) este dispositivo debe aceptar toda interferencia
que reciba, incluso la que pudiera causar un funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio
o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo. Estas
modificaciones podrían anular la autoridad del usuario para utilizar este equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para dispositivos digitales de
Clase B, de conformidad con el apartado 15 de la normativa de la FCC. Estos límites están
diseñados para proveer protección razonable contra interferencias perjudiciales en instalaciones
residenciales. Este equipo genera, usa y puede irradiar energía de radiofrecuencias y, si
no se instala y usa según las instrucciones, puede provocar interferencia perjudicial a las
radiocomunicaciones. No obstante, no hay garantías de que no ocurrirá interferencia en una
instalación en particular. Si este equipo provoca interferencia perjudicial a la recepción de
radio o televisión, lo que puede determinarse encendiendo y apagándolo, se recomienda que
el usuario intente corregir la interferencia aplicando una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente
del circuito al que el receptor está conectado.
— Consultar al distribuidor o a un técnico con experiencia en
radio/televisión para solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
FCC — U2ZZW4103 | IC: 6924A‑ZW4103
Jasco Products Company | Model: ZW4103 / 39337
CAN ICES‑3(B) / NMB‑3(B)
All brand names shown are trademarks
Tous les noms de marque illustrés
Todos los nombres de marca
of their respective owners.
sont des marques de commerce
que aparecen son marcas
de leurs propriétaires respectifs.
comerciales pertenecientes a
sus respectivos propietarios.
The Honeywell Trademark is used under license from Honeywell International Inc.
Honeywell International Inc. makes no representation or warranties with
respect to this product.
This product is manufactured by Jasco Products Company LLC.
MADE IN CHINA/FABRIQUÉ EN CHINE/ HECHO EN CHINA
©JASCO 2017 | 39337 | ZW4103 | 10/04/17 v1
Jasco Products Company LLC.
10 E. Memorial Rd.,
Oklahoma City, OK 73114
1
FEATURES
Total maximum load for the Z‑Wave controlled outlet:
600W(5A) Incandescent or 1800W(15A)
Resistive or ½ HP Motor.
• One Z‑Wave controlled AC outlet for standard
incandescent lighting, xenon, halogen, CFL/
LEDs, fans or small appliances
• Remote ON/OFF via the Z‑Wave controller
• Manual ON/OFF control with the
top-mounted push button
• Space-efficient design
• Does not block the lower outlet when plugged
into the upper outlet of a duplex wall receptacle
(this assumes that the duplex receptacle is
mounted with the ground pin down)
• Plugs and cords for connected devices route to
the side allowing close placement of furniture
• Grounded 3-wire power connection for safety
• This Z‑Wave device has advanced features that allow you
to customize your experience — these features can only
be adjusted by a Z‑Wave enabled controller that supports
the Z‑Wave Configuration command class. For a complete
list of Adjustable Configurations, visit: www.byjasco.com
3
INSTALLATION
Plug the device you want to control into the
1.
Z‑Wave controlled outlet on the smart switch.
Plug the smart switch directly into an available
2.
grounded outlet (top outlet recommended if possible).
NOTE: Plug directly into outlet.
Do not use with extension cords.
SMART SWITCH
PLUG-IN
INTERRUPTEUR INTELLIGENT
ENFICHABLE
INTERRUPTOR INTELIGENTE
ENCHUFE
Z-W
® C
W
l
C
ave
ertified
ireless
ighting
ontrol
C
'
Z-W
®
ommande d
éClairage sans fil Certifiée
ave
Z-W
® C
i
i
ave
ontrol de
luminaCión
nalámbriCo CertifiCado
Scan to view installation guide
Balayez ce code pour consulter le guide d'installation
Explore para ver la guía de instalación
www.byjasco.com
2
FUNCTION
A
4
OPERATION
The manual/program button on the
smart switch allows the user to:
• Manually turn the connected device
ON or OFF (press and release).
• Add/remove the smart switch from the network.
DO NOT RETURN THIS
PRODUCT TO THE STORE
NE RETOURNEZ PAS CE
STOP
PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
If you have any problems or questions, contact our tech support
team at 1‑855‑698‑8324, Monday–Friday, 7AM–8PM CST.
For the most up-to-date product support, accessories, electronic
(PDF) format manuals and more, visit www.byjasco.com/support.
• No user serviceable parts in this unit.
Si vous avez des problèmes ou des questions, communiquez avec notre équipe de
soutien technique au 1‑855‑698‑8324, du lundi au vendredi, de 7 h à 20 h (HNC).
Pour un soutien technique d'avant-garde, les nouveaux accessoires,
les plus récents manuels en format électronique (PDF) et plus
encore, visitez le site www.byjasco.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l'utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro equipo
técnico al número: 1‑855‑698‑8324, de lunes a viernes,
de 7.00 a 20.00, hora estándar del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos, accesorios,
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support
• Esta unidad no contiene piezas que el usuario pueda reparar.
WARNING
RISK OF FIRE
RIESGO DE INCENDIO
RISK OF ELECTRICAL SHOCK
RIESGO DE DESCARGA ELÉCTRICA
RISK OF BURNS
RIESGO DE QUEMADURAS
TO REDUCE THE RISK OF ELECTRIC
PARA REDUCIR EL RIESGO DE DESCARGAS
SHOCK, THIS PRODUCT HAS A
ELÉCTRICAS, ESTE PRODUCTO TIENE
GROUNDING TYPE PLUG THAT HAS A
UN ENCHUFE DE CONEXIÓN A TIERRA
THIRD (GROUNDING) PIN. THIS PLUG
CON UNA TERCERA PATA (DE CONEXIÓN
WILL ONLY FIT INTO A GROUNDING
A TIERRA). ESTE ENCHUFE ES APTO
TYPE POWER OUTLET. IF THE PLUG
SOLAMENTE PARA TOMACORRIENTES DE
DOES NOT FIT INTO THE OUTLET,
CONEXIÓN A TIERRA. SI EL ENCHUFE NO
CONTACT A QUALIFIED ELECTRICIAN
ENTRA EN EL TOMACORRIENTE, LLAME
TO INSTALL THE PROPER OUTLET. DO
A UN ELECTRICISTA MATRICULADO
NOT CHANGE THE PLUG IN ANY WAY.
PARA QUE INSTALE EL TOMACORRIENTE
CORRECTAMENTE. NO MODIFIQUE EL
CONTROLLING APPLIANCES:
ENCHUFE DE NINGUNA MANERA.
CAUTION: TO REDUCE THE RISK
OF OVERHEATING AND POSSIBLE
CONTROL DE APARATOS:
DAMAGE TO OTHER EQUIPMENT.
PRECAUCIÓN: A FIN DE DISMINUIR
EL RIESGO DE RECALENTAMIENTO
• DO NOT EXCEED RATINGS
Y DE POSIBLES DAÑOS EN
• DO NOT USE TO CONTROL ANY DEVICE
LOS DEMÁS EQUIPOS.
WHERE UNINTENDED OPERATION
• NO SUPERAR LOS VALORES
COULD CAUSE UNSAFE CONDITIONS
NOMINALES ELÉCTRICOS.
(HEAT LAMP, SUN LAMP, ETC.)
• NO USAR PARA CONTROLAR
DISPOSITIVOS EN LOS QUE
AVERTISSEMENT
EL FUNCIONAMIENTO NO
INTENCIONADO PODRÍA PROVOCAR
SITUACIONES PELIGROSAS
RISQUE D'INCENDIE
(LÁMPARAS DE CALEFACCIÓN,
RISQUE DE CHOC ÉLECTRIQUE
LÁMPARAS SOLARES, ETC.)
RISQUE DE BRÛLURES
POUR RÉDUIRE LES RISQUES DE CHOC
ÉLECTRIQUE, CE PRODUIT COMPREND
NOT FOR USE WITH MEDICAL OR
UNE FICHE MISE À LA TERRE CONSTITUÉE
LIFE SUPPORT EQUIPMENT
D'UNE TROISIÈME BROCHE (MISE À LA
Z‑WAVE ENABLED DEVICES SHOULD
TERRE). CETTE FICHE NE PEUT ÊTRE
NEVER BE USED TO SUPPLY
INSÉRÉE QUE DANS UNE PRISE DE
POWER TO, OR CONTROL THE ON/
COURANT À LA TERRE. SI LA FICHE NE
OFF STATUS OF MEDICAL AND/
PEUT ÊTRE INSÉRÉE DANS LA PRISE,
OR LIFE SUPPORT EQUIPMENT.
COMMUNIQUEZ AVEC UN ÉLECTRICIEN
QUALIFIÉ QUI INSTALLERA UNE PRISE
NE PAS UTILISER AVEC UN
ADÉQUATE. NE CHANGEZ PAS LA PRISE
ÉQUIPEMENT MÉDICAL
DE QUELQUE MANIÈRE QUE CE SOIT.
OU DE SURVIE
LES DISPOSITIFS COMPATIBLES
COMMANDE DES APPAREILS :
AVEC LA TECHNOLOGIE Z‑WAVE NE
ATTENTION : POUR RÉDUIRE LE RISQUE
DEVRAIENT JAMAIS ÊTRE UTILISÉS
DE SURCHAUFFE ET DE DOMMAGES
POUR ALIMENTER OU COMMANDER
POSSIBLES À D'AUTRES APPAREILS,
LA MISE EN MARCHE OU L'ARRÊT DE
• NE PAS DÉPASSER LES
L'ÉQUIPEMENT MÉDICAL OU DE SURVIE.
CARACTÉRISTIQUES NOMINALES
SE PROHÍBE SU EMPLEO EN
• NE PAS UTILISER POUR COMMANDER
EQUIPO MÉDICO O EQUIPO
DES APPAREILS POUR LESQUELS
PARA EL MANTENIMIENTO DE
UN FONCTIONNEMENT IMPRÉVU
LAS FUNCIONES VITALES
POURRAIT ENTRAÎNER DES
CONDITIONS DANGEREUSES (LAMPE
LOS DISPOSITIVOS Z‑WAVE NUNCA
INFRAROUGE, LAMPE SOLAIRE, ETC.)
SE DEBEN USAR PARA SUMINISTRAR
ENERGÍA ELÉCTRICA, NI PARA
CONTROLAR EL ESTADO DE ENCENDIDO
O APAGADO DEL EQUIPO MÉDICO Y/O
39337
EL EQUIPO PARA EL MANTENIMIENTO
ZW4103
DE FUNCIONES VITALES.
B
C
5
CONNECTION
ADDING YOUR DEVICE TO A Z-WAVE NETWORK
Follow the instructions for your Z‑Wave certified
1.
controller to add a device to the Z‑Wave network.
Once the controller is ready to add your device,
2.
press and release the manual/program button
on the smart switch to add it in the network.
Now you have complete control to turn your device
ON/OFF according to groups, scenes, schedules and
interactive automations programmed by your controller.
If your Z‑Wave certified controller features remote access,
you can now control your fixture from your mobile devices.
WARRANTY
JASCO Products warrants this product to be free from manufacturing defects for a
period of two years from the original date of consumer purchase. This warranty is limited
to the repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product. This warranty is
in lieu of all other warranties, expressed or implied. Some states do not allow limitations
on how long an implied warranty lasts or permit the exclusion or limitation of incidental
or consequential damage, so the above limitations may not apply to you. This warranty
gives you specific rights and you may also have other rights which vary from state to state.
Please contact Customer Service at 855‑698‑8324 between 7AM – 8PM CST or via our
website (www.byjasco.com) if the unit should prove defective within the warranty period.
GARANTIE
JASCO Products garantit que ce produit est exempt de tout défaut de fabrication pour une
période de deux ans à compter de la date de l'achat original par l'acheteur. Cette garantie
se limite exclusivement à la réparation ou au remplacement de ce produit et n'est pas
applicable aux dommages indirects ou accessoires survenus sur d'autres produits utilisés
avec ce produit. Cette garantie se substitue à toute autre garantie expresse ou implicite.
Certains États ne permettent pas de restrictions quant à la durée d'une garantie implicite
ou permettent l'exclusion ou la limitation des dommages indirects et accessoires; il se
peut, par conséquent, que cette garantie ne s'applique pas dans votre cas. Cette garantie
vous confère des droits juridiques précis; vous pouvez jouir d'autres droits qui peuvent
varier d'un État à l'autre. Veuillez communiquer avec le service à la clientèle au 1‑855‑
698‑8324, du lundi au vendredi, de 7 h à 20 h (HNC) ou par l'intermédiaire de notre site
Web (www.byjasco.com) si l'appareil s'avère défaillant au cours de la période de garantie.
GARANTÍA
Jasco Products garantiza que este producto no tendrá defectos de fabricación durante dos años
a partir de la fecha de compra del consumidor original. Esta garantía se limita a la reparación o
reposición de este producto y no cubre daños indirectos o incidentales a otros productos que se
pudieran utilizar con este producto. Esta garantía reemplaza cualquier otra garantía explícita o
implícita. Algunos estados no permiten la aplicación de limitaciones respecto de la duración de
una garantía implícita o permiten la exclusión o limitación de la cláusula sobre daños indirectos
o incidentales, por este motivo las limitaciones arriba mencionadas pueden no aplicarse en su
caso. Esta garantía le otorga derechos específicos y es posible que tenga otros derechos que
pueden variar según el estado en el que vive. Póngase en contacto con Atención al Cliente al 855‑
698‑8324 entre las 7:00 y las 20.00 CST (hora central estándar) o a través de nuestro sitio web
(www.byjasco.com) en caso de que se produzca algún defecto durante la vigencia de la garantía.
ADVERTENCIA
JASCO Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
Power 120VAC, 60Hz
Signal (Frequency) 908.4 / 916 MHz
Total maximum load for the Z‑Wave controlled outlet:
600W(5A) Incandescent, ½ HP Motor or 1800W (15A) Resistive
Range: Up to 150 feet line of sight between the Wireless Controller
and the closest Z‑Wave receiver module.
Operating Temperature Range: 32–104° F (0–40° C)
For indoor use only.
SPÉCIFICATIONS
Alimentation : 120 V c.a., 60 Hz
Signal (fréquence) : 908,4/916 MHz
Charge maximale totale pour la prise commandée Z‑Wave : lampe à incandescence
de 600 W (5 A), moteur de ½ HP ou résistance de 1 800 watts (15 A)
Portée : Distance à vue maximale de 150 pi entre la télécommande
et le module de réception Z‑Wave le plus proche.
Plage de températures de fonctionnement : de 32 à 104 °F (de 0 à 40 °C)
Utilisation intérieure uniquement.
En raison d'améliorations continues du produit, les spécifications
peuvent faire l'objet de changements sans préavis.
ESPECIFICACIONES
Corriente eléctrica: 120 VCA, 60 Hz
Señal (frecuencia): 908.4/916 MHz.
Carga máxima para el tomacorriente controlado por Z‑Wave: 600 W (5 A),
incandescente, motor de ½ HP o 1800 W (15 A) de carga resistiva
Alcance: hasta 150 pies, sin obstrucciones, entre el controlador
inalámbrico y el módulo receptor Z‑Wave más cercano.
Rango de temperatura de funcionamiento: 32‑104 °F (0‑40 °C)
Para uso en interiores exclusivamente.
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z‑Wave network with other Z‑Wave certified
devices from other manufacturers and/or other applications. All non-battery operated nodes
within the network will act as repeaters regardless of vendor to increase reliability of the network.
INTEROPÉRABILITÉ ENTRE LES DISPOSITIFS Z-WAVE
Ce produit peut être utilisé dans un réseau Z‑Wave avec d'autres appareils
certifiés Z‑Wave produits par d'autres fabricants et d'autres applications. Tous les
nœuds fonctionnant sans pile au sein du réseau joueront le rôle de répétiteurs,
quel que soit le fournisseur, afin de rehausser la fiabilité du réseau.
INTEROPERABILIDAD Z-WAVE
Este producto se puede incluir y puede funcionar en cualquier red Z‑Wave con dispositivos
de otros fabricantes y otras aplicaciones que cuenten con la homologación Z‑Wave. Todos
los nodos que formen parte de la red y que funcionen sin pilas actuarán de repetidores
independientemente del proveedor con el fin de aumentar la fiabilidad de la red.
Z-Wave controlled outlet
A.
This outlet can remotely turn ON/
OFF the connected device
Manual/Program button
B.
Single press — turn the lamp ON/OFF
1.
Single press — add or remove in Z‑Wave network
2.
LED (behind button)
C.
Default — the LED light under the program
1.
button will light when connected lamp is on.
Invert — to have the LED light on when the
2.
connected lamp is off, quickly press the
program button 10 times.
NOTE: Device must be connected to a Z-Wave network.
TO REMOVE AND RESET THE DEVICE
Follow the instructions for your Z‑Wave certified
1.
controller to remove a device from the Z‑Wave network.
Once the controller is ready to remove your device,
2.
press and release the manual/program button on
the smart switch to remove it from the network.
TO RETURN YOUR SWITCH TO FACTORY DEFAULTS
If plugged in, unplug the device from the receptacle.
1.
Press and hold the top button, plug the device in,
2.
and continue to hold for at least 3 seconds.
Note: This should only be used in the event your network's
primary controller is missing or otherwise inoperable.
This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Switch Binary Report
• Association Group 2 supports Basic Set and
is controlled with the local load
• Association Group 3 supports Basic Set and is
controlled by double pressing the button
• Each Association Group supports 5 total nodes

Publicidad

loading

Resumen de contenidos para Honeywell Z-Wave ZW4103

  • Página 1 ENERGÍA ELÉCTRICA, NI PARA The Honeywell Trademark is used under license from Honeywell International Inc. CONTROLAR EL ESTADO DE ENCENDIDO INTEROPÉRABILITÉ ENTRE LES DISPOSITIFS Z-WAVE O APAGADO DEL EQUIPO MÉDICO Y/O...
  • Página 2 CARACTÉRISTIQUES FONCTION Charge maximale pour la prise commandée Z‑Wave : Prise commandée Z-Wave lampe à incandescence de 600 W (5 A), résistance Cette prise peut allumer et éteindre à de 1 800 watts (15 A) ou moteur de ½ HP. distance l’appareil connecté.
  • Página 3 39337 / ZW4103 ADVANCED OPERATION The following Advanced Operation parameters require that you have an advanced controller. Basic remotes do not have this capability. All On/All Off Depending upon your primary controller, the 39337 Plug-in module can be set to respond to ALL ON and ALL OFF commands in up to four different ways.