Descargar Imprimir esta página

Symmons Allura S-240-2-LAM-RP Instrucciones De Instalación Y Mantenimiento página 3

Grifo de lavabo

Publicidad

Idiomas disponibles

Idiomas disponibles

fasten to end of
clevis strap in the
up position and
stopper is in the
closed position.
Insert
lift rod into
end of clevis strap
and fasten with
thumb screw at
location where
stopper can be
easily opened and
closed.
If necessary, select
another location
hole in clevis strap
and re-adjust lift
rod where fastened to clevis strap to ensure easy operation.
Step 7 Attach drain body to drain trap
Step 8 Flush water supply lines
Th oroughly fl ush supply
lines to prevent foreign
matter, i.e. copper chips,
sand, etc. from damaging
the sealing surface inside
control valves.
Remove
aerator from
end of faucet spout
by rotating counter
clockwise
Turn hot and cold
faucet handles to full
ON
sup ply valves long enough to fl ush supply lines thor ough ly.
Turn faucet
, replace aerator and check for any leaks.
OFF
Care of faucet fi nish
Clean fi nish area by using mild soap and water or non-abrasive
cleaners and then rinse immediately. A non-abrasive wax may
be used to preserve fi nish area.
Dimensions
Allura Lavatory Faucet, S-240 Series
4-1/4"
4-1/4"
108 mm
108 mm
2-9/16"
65 mm
2-1/4"
57 mm
2"
51 mm
4"
102 mm
6"
152 mm
N t
lift rod
small plug
clevis strap
thumb
screw
location
hole
spring clip
pivot rod
remove
aerator
position and then open water
3-3/8"
79 mm
1-3/8" max.
35 mm
2-1/8"
1/2"-14 NPSM
54 mm
Hole diameter
1" (25 mm)
4-1/2"
114 mm
Valve cartridge replacement
Valve cartridge replacement
1
2
3
Page 3
COLD water
cartridge identified
by grooves