The cut-off load is factory set on the basis of the operating specifications of the
winch.
Upon reaching the load threshold in the selected speed, power to the motor is cut
for 5 seconds for the first speed or 5 seconds for the second speed. Until the preset
time has elapsed, the device prevents the use of the winch only in the speed in
which the load threshold was reached.
CAUTION! In the event that the winch stops operating due to an overload,
reduce the load before using it again.
N.B.: If the threshold relating a speed has been reached and the preset
period of time has not expired, the speed cannot be enabled.
SPECIFICATIONS/CONDITIONS FOR USE
This section contains the technical specifications of the device.
Environmental limits
Operating temperature ....................................... -10
Storage temperature .......................................... -10
Operating relative humidity ................................ 0
Operating voltage limits
For models rated at 12 Vdc ................................ 9 V
For models rated at 24 Vdc ................................ 18 V 32 V
Shut-off threshold due to flat battery
For models rated at 12 Vdc ................................ 9 V (operation restored above 10 V)
For models rated at 24 Vdc ................................ 8 V (operation restored above 20 V)
12
60°C
85°C
90 %
16 V
132