Radial-Rohrventilator RRK 180 / 200 / 250 Ex
Ventilateur Centrifue RRK 180 / 200 / 250 Ex
Centrifugal 'In-Line' Duct Fan RRK 180 / 200 / 250 Ex
GB
– Maximum permissible temperature of the
medium to be delivered +50 °C.
– Fans designed for use in explosive atmosphe-
res must be safeguarded against foreign
bodies being dropped or suctioned into the
fan. Ball bearings must be checked at least
once a year for smooth running, and if neces-
sary exchanged for new ball bearings lubrica-
ted with original bearing grease.
– In order to comply with the safety requirements
of the Appliance Safety Act, a protective grille
in accordance with DIN EN ISO 13857 must be
used in the event of a free intake or outlet on
the side in question.
– The fans are produced in compliance with DIN
VDE 0170/0171 and VDMA 24169 Parts 1 and
2. When installing (exclusively in zones 1, 2),
due attention must be paid to the valid regulati-
ons, in particular to DIN VDE 0165.
– The fan is designed in accordance with VDE
safety requirements within the scope of the
Appliance Safety Act and the valid stipulations
of the EC directives.
Mounting
– Fig. 2: Pipe connection on both ends.
– Fig. 3: Free intake, free exhaust.
Œ Fan
* Capacitor and ** terminal box
Ž Ducting to be supplied by customer.
 Flexible sleeve FM...EX with tightening straps
(accessory) should be used as connection
between ducting Ž and fan Œ.
 Base MK 4 (accessory):
Can be fitted by means of supplied selftaping
screws in the mounting area on the fan cir-
cumference (p. 22), depending on the requi-
red position of the terminal box **. Rough
drill Ø 3,5 mm if possible.
‘ Slip-on reducing fitting (accessory) to serve
as connection between fan À and ducting Ž.
’ Grille (accessory):
Can be fitted by means of supplied selftap-
ping screws. Break out predetermined brea-
king points in the grille. Rough drill Ø 3,5 mm
if possible.
“ Ceiling, wall, bearer.
– The appliance conforms to the protection class
specified on the rating plate when mounted
GB
horizontally. i. e. for delivery on the downward
direction.
– Suitable for any mounting position in dry
rooms.
– For intake or exhaust operation, depending on
mode of fitting.
– The direction of air flow and rotation is marked
on the fan sleeve by arrows.
Technical Data
See the rating plate or valid catalogue.
Electrical connection
In accordance with the wiring diagram in Fig. 4.
– Subject to change! –