Start-up procedure

After pump installation, the system can be started
by using the following procedure:
• Make sure suction hose is connected to the
water supply.
• Open the spray nozzle and start the pump.
• Close the spray nozzle when water begins flowing
and all air has been purged from the system.
• If additional spray nozzles or taps are in use
after the pump, open each additional nozzle/tap
until all air has been purged from the system.
• Pump will shut off after taps are closed
and pressure builds to the setpoint of the
pressure switch
Self-priming
Pump is self-priming up to 8.2 ft (2.5m). Intake
lines must be air-tight to ensure self-priming.
Dry running
Pump will not be damaged by shorter period
of dry running. It will, however, unnecessarily
reduce your battery power.
CAUTION: Do not use pump for any liquids other
than fresh water and sea water.
Temperature
Max liquid temperature: +120°F (+50°C)
Max ambient temperature: +140°F (+60°C)
WDS_-InstructManual.indd 
There's nothing more important to us than customer satisfaction.
If you have any questions or your purchase does not meet your
expectations, please do one of the following:
• Contact your local West Marine store
• Call 1-800-BOATING
• Contact us at www.westmarine.com
Winterizing
If water is not drained from the system during
freezing temperatures, damage is likely to be
sustained in the plumbing and in the pump. To
prevent damage follow the instructions below:
1. Disconnect suction hose from water supply
(sea water supply) or if water supply is taken
from a tank, drain water storage tank.
2. Open all spray nozzles/taps.
3. Run pump until remaining water is expelled.
4. Disconnect inlet and outlet tubes.
5. Run pump briefly to confirm that water has
been expelled.
6. Spray nozzles/taps shall remain open and
pump fittings shall remain disconnected until
temperatures are above freezing
Never start a frozen pump. Even if it is drained
it might contain a small amount of frozen water
that locks the rotor.