Vimar ELVOX TAB 7509/D Serie Instrucciones Instalador - Manual Do Instalador página 10

Ocultar thumbs Ver también para ELVOX TAB 7509/D Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
TAB: 7509
Configurations
Choice of ringtones
10 different ringtones can be selected. Different ringtones can also be set
for outdoor, intercommunicating and door calls (see below). The ringtones
must be selected with the interphone/monitor on stand-by and the handset
on the hook.
The button for entering configuration mode is button A (self-start).
Button E1 selects the ringtone for ENTRANCE PANEL CALL.
Button E2 selects the ringtone for INTERCOMMUNICATING CALL.
Button E3 selects the ringtone for DOOR CALL (exclusively using the button
interface module 6120 or Vimar landing call button). In the case of a door
call by means of a button connected directly to the interphone's terminals
FP and M, the ringtone cannot be changed.
Configuration:
1) Press button A (self-start) and hold down (for 2 s) until the LED G "door/
gate open" begins flashing and the interphone emits an audible signal.
2) Press and hold down the button for the chosen ringtone (button E1/
button E2/button E3) until the ringtone is heard on the interphone.
3) Press the button repeatedly (button E1/button E2/button E3) to select
the desired type of ringtone.
4) After choosing the desired ringtone, press button A or refrain from
touching any buttons for 5s to save. After completing the configuration,
the LED flashes and then turns off.
Ringtone volume adjustment
The ringtone volume can be set to 6 levels plus mute.
Press button A (self-start) to enter configuration mode.
Press button B (bell) to lower the ringtone volume.
Press button C (key) to increase the ringtone volume.
The ringtone volume must be adjusted with the interphone/monitor on
stand-by and the handset on the hook.
Configuration:
1) Press button A (self-start) and hold down (for 2 s) until the LED G "door/
gate open" begins flashing and the interphone emits an audible signal.
3) Press button B to lower or button C to increase the volume. Each time
the buttons are pressed the volume changes by one level.
4) After choosing the desired volume, press button A or refrain from touch-
ing any buttons for 5s to save. After completing the configuration, the
flashing LED goes off and a "beep" is emitted.
Muting the ringtone (User Away function)
Using the volume adjustment procedure described above, pressing button
B a sufficient number of times results in the ringtone being muted. The
"Ringtone muted" status is indicated by the LED F (ringtone muted) lighting
up steadily.
If the interphone receives a call from the entrance panel while the ringtone
is muted, this is indicated by the LED F (ringtone muted) emitting one flash
for each unanswered call up to a maximum of 4 calls (these flashes occur
every 10 s). When the ringtone volume is restored, at least to its minimum
level, this indication will be reset.
10
Installation
Dimensions:
180 mm
External wall mounting
- Install the interphone away from sources of light and heat.
- To open the interphone, raise the lid by levering with the fingers and if
necessary pushing with a screwdriver at the two engagement points on
the bottom of the interphone to separate the cover from the base (Fig. 6).
- Fix the interphone base (Fig. 4): directly to the wall by means of two ex-
pansion plugs or to a unified 3-module rectangular flush-mount back box
(Vimar V71303 type) installed vertically or a round flush-mount back box
(60 or 70 mm). Two expansion plugs to be used for fixing directly to the
wall and two screws for fixing to a round flush-mount box are provided.
- We recommend installing the interphone with its lower edge at a height
of 1.40 m from the floor.
- Make the connection to the terminal block connected to the interphone
base as shown in the wiring diagrams.
- Close the interphone by hooking the top edge of the cover over the base
and then applying light pressure at the bottom until it clicks into place (Fig.
7).
Fig. 4
EN
105 mm
35 mm
1,40 m
Fig. 3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elvox tab 7509

Tabla de contenido