Hilti TE 30 Manual Del Usuario página 12

Ocultar thumbs Ver también para TE 30:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

▶ You and any other persons in the vicinity must wear suitable eye
protection, a hard hat, ear protection, protective gloves and respiratory
protection while the tool is in use.
▶ Wear protective gloves also when changing the accessory tool. Touching
the accessory tool can result in cuts and burns.
▶ Wear eye protection. Flying fragments can injure the body and eyes.
▶ Before starting work, check the hazard class of the dust that will
be produced when working. Use an industrial vacuum cleaner with
an officially approved protection class in compliance with the locally
applicable dust protection regulations. Dust from materials such as
lead-based paint, certain types of wood and concrete/masonry/stone
containing quartz, minerals or metal can be harmful to health.
▶ Make sure that the workplace is well ventilated and, where necessary,
wear a respirator appropriate for the type of dust generated. Contact with
or inhalation of the dust may cause allergic reactions and/or respiratory
or other diseases among operators or bystanders. Certain kinds of dust
are classified as carcinogenic such as oak and beech dust, especially
in conjunction with additives for wood conditioning (chromate, wood
preservative). Material containing asbestos may be handled only by
specialists.
▶ Take breaks and do physical exercises to improve the blood circulation
in your fingers. Exposure to vibration during long periods of work can
lead to disorders of the blood vessels and nervous system in the fingers,
hands and wrists.
Electrical safety
▶ Before beginning work, check the working area for concealed electric
cables or gas and water pipes. External metal parts of the power tool
can become live, presenting a risk of electric shock, if you accidentally
damage an electric cable.
Careful handling and use of electric tools
▶ Wait until the power tool stops completely before you lay it down.
3
Description
3.1 Overview of the product
Chuck
@
Depth gauge release button
;
Depth gauge
=
Function selector switch
%
Active Vibration Reduction
&
(AVR)
6
English
1
Control switch
(
Grip
)
Supply cord
+
Forward / reverse switch
§
Side handle
/
2143374
*2143374*

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Te 30-avr

Tabla de contenido