Suitable Use Of The Machine; Electrical Connection - Renson 160991 Manual Del Usuario

Hidrolipiadora de alta presión en caliente
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
must have the dimensions shown in the
table below.
230-240V
3G 2,5 mm
2
max 20 m
(if fitted)
Machines equipped with delayed, low-voltage Total
Stop with intelligent switch-off:
When the machine is working, by releasing the gun
lever, after approximately 15 seconds the motor
stops automatically to prevent component wear
during the pump by-pass phase (motor in stand-by).
By pressing the gun lever the motor starts automa-
tically.
•WARNING: do not leave the stand-by mode
active for more than 5 minutes.
If the machine remains in stand-by mode for more
than 20 minutes, it switches off automatically and
completely: in fact, by pressing the gun lever the
machine does NOT start working.
For this reason, if you need to start the machine it
is necessary to set the switch to (0) "OFF" and then
to (I) "ON".
At the end of the operation, set the switch to "OFF".
Activate hand spray gun until device is pressure less.
PRESSURE REGULATOR:
If the appliance is equipped with a pressure
regulator:
- when the pressure is set to minimum the T.S.
may not trigger. Therefore, do not allow the
appliance to function in by-pass for more than
1 minute.
- do not act on the gun lever too frequently (this
may cause a malfunction).
>

SUITABLE USE OF THE MACHINE

The performances of the machine are suitable
for a professional use. Structural technologies
have been studied to assure high reliability and
safety levels, and long life. It is absolutely for-
400-415V
4G 2,5 mm
2
max 30 m
bidden to use the machine in potentially explo-
sive environments or areas.
The working temperature must range between
+ 5° and + 50°C. It is forbidden to carry out any
modification to the structure and to any ele-
ments of the machine.
CORRECT USE OF THE MACHINE
• The cleaner must be placed on a firm, stable
surface and must be horizontal.
• In case of operation indoors, adequate venti-
lation and gas venting must be assured.
• Whenever using the high-pressure cleaner,
users are urged to hold the gun in the correct
position, with one hand on the grip and the
other on the spray rod.
• The water jet must never be pointed at the
electrical cables or at the machine.
>
INSTALLATION AND START-UP
INSTALLATION
The equipment must be installed on a sturdy,
perfectly flat surface. Fasten to the floor with 4
steel wedges Ø 1 (see ref. 2).
The floor must be suitable for this kind of fas-
tening.
1
START-UP
ST
When starting up for the first time or after a
long period out of use, connect the intake line
only for a few minutes so that any dirt is vented
from the delivery outlet.

ELECTRICAL CONNECTION

Check that the mains voltage is the same as
that of your machine, indicated on the techni-
cal data plate. Your electrical system must be
constructed by qualified technicians capable of
working in accordance with the requirements
of the regulations in force (earth connection,
fuses, differential security breaker, etc).
The connection to the mains must be carried
out by qualified personnel.
Connect a supply cable whose diameter is suit-
able for the power used by the equipment (see
Technical Data).
Connect the ground cable together with the
other ground cables located inside the electric
box.
In case of failure to comply with one of the
EN
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

160992