Descargar Imprimir esta página
Honeywell Home PROWLTOUCH Guía Rápida Del Usuario
Honeywell Home PROWLTOUCH Guía Rápida Del Usuario

Honeywell Home PROWLTOUCH Guía Rápida Del Usuario

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

General Information
The PROWLTOUCH is a wireless Touchscreen that allows you to perform security and automation functions, as well as to monitor the status of your security system
Navigating Menus
System Status is displayed on the left side of the screen and the time and date are displayed at the top-right of the Security Screen. The Security Screen displays the system status and selection "icons".
The displayed pages and options may vary slightly depending upon the devices and services that are installed in or connected to the system.
Arm the System
Steps
Icons
1
If the system is "Ready to Arm", touch the
2
Select
Select
armed
Select
detectors will be armed.
3
Enter user code.
• System arms in selected mode
• Exit Delay countdown begins
• Keypad beeps begin, if enabled (Silent Exit mutes countdown beeps)
• Keypad will not display if your installer has "Quick Arm" feature enabled in the
system.
Panic Alarms
See your installer for types of Panic alarms programmed for your system.
Steps
Icons
1
Select the Panic icon in the bottom-left of most screens
2
Select the Fire icon to alert the monitoring company that a fire condition exists.
(Displays zone 995) OR
Select the Police icon to alert the monitoring company that a police emergency
exists. (Displays zone 999, default is silent) OR
Select the Medical icon to alert the monitoring company to other types of
emergency. (Displays zone 996)
Assign User Codes
Steps
Icons
1
Select the Menu
2
Scroll down and select Settings icon.
User
3
Select "User Management"
Management
4
Enter the current Master or Partition Master Code. The default Master Code is
1234.
+
5
Select the " + " icon in the top-right of the screen
6
Enter the user's name and select "SAVE".
Name Label
7
Select the Pencil icon to the right of the "Pin" box. Then, enter the 4-digit user
code for the new user.
8
Partition Access
Select the down arrow to the right of each partition to give the user an Authority
/ Authority Level
Level for that partition.
• None – User will not work in partition
• User – User can arm, disarm, and bypass in partition
• Guest – User can disarm only if it was used to arm
• Arm Only – User can arm only and cannot disarm
• Partition Master – Same as Master code, but cannot change the Master
code
• Duress – Wil send a Duress signal to the Central Monitoring center when
used to disarm the system.
9
Bluetooth
Select "Bluetooth Disarming" to pair the user's Bluetooth device. This will allow
(OPTIONAL)
automatic disarming of the system when the user's Bluetooth device is within
range.
10
Once complete, select
11
Enter the current Master or Partition Master Code. The default Master Code is
1234. The new user is displayed on the list.
Ê800-25192B]Š
800-25192B
6/19
Rev. B
PROWLTOUCH Wireless Touchscreen
Commands
button.
when you're away from home
OR
when you'll be home, and all motion detectors are not
OR
when you'll be home at night, but certain motion
Commands
Commands
icon.
.
Quick User Guide
Bypassing Zones
Steps
Icons
1
2
3
1
1
2
3
4
<
5
Menu
Icon
Name
Menu
Favorites
Devices
Sensors
Cameras
Scenes
Events
Settings
Tools
Test the System
Disarm the system and close all zones so the system is "Ready to Arm".
NOTE: These tests will not generate alarm messages. No alarm signals are sent to your monitoring company.
Steps
Icons
1
2
3
System Tests
4A
Test
Communicator
4B
Sensor Test
4B
4B
Fault Sensors
5
Wireless Touchscreen
.
Commands
Select
.
Enter the 4-digit code.
Select
, then, select your arming mode; AWAY, HOME, or
NIGHT.
OR
If "Force Bypass" feature is enabled by your installer, select
to automatically bypass all faulted zones, then select your arming
mode; AW AY, HOME, or NIGHT
OR
Select
to display a list of faulted zones. Select each zone to
bypass by touching the box to the far right of each zone.
Select
.
Enter your 4-digit user code.
Select the back " < " icon.
Select
, then select your arming mode; AWAY, HOME or
NIGHT.
Options
Provides access to the list of options below.
Access selected Z-Wave devices for quick access
Provides access to Z-Wave Devices and Z-Wave Management
Provides access to Zone information and options
Provides access to cameras
Provides access to Scenes for Z-Wave Automation programming.
Provides access to system Activity Log.
Provides access to Wi-Fi settings, User Management, and Voice Services
(Amazon Alexa)
Provides access to System Info (Version, MAC and ID's), System Tests
(Communicator and Sensors), and System Reboot
Commands
Select the Menu
icon. Scroll up or down through the menu options.
Scroll down and select the "Tools" icon. Then, enter the Master code.
Select "Test Communicator" or "Test Sensors"
This will give you the option to select "Test Wi-Fi", "Test Cellular" or "Test
Both". The system will display test results.
Select "Test Sensors". You will see a list of sensors programmed in your
system.
Select
. The system's sounder will sound for a half second.
Activate each zone. The system will provide chime beeps and annunciate
each zone along with displaying the signal and battery levels.
When testing is complete, select
PROWLTOUCH
.

Publicidad

loading

Resumen de contenidos para Honeywell Home PROWLTOUCH

  • Página 1 Quick User Guide General Information The PROWLTOUCH is a wireless Touchscreen that allows you to perform security and automation functions, as well as to monitor the status of your security system Navigating Menus System Status is displayed on the left side of the screen and the time and date are displayed at the top-right of the Security Screen. The Security Screen displays the system status and selection “icons”.
  • Página 2 FIRE AND CARBON MONOXIDE ALARM OPERATION FEDERAL COMMUNICATIONS COMMISSION & ISED STATMENTS Your fire alarm system and carbon monoxide detector (if installed) is on 24 hours a The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual.
  • Página 3: Renseignements Généraux

    Guide de référence rapide Renseignements généraux PROWLTOUCH est un écran tactile sans fil qui vous permet d’armer et de désarmer un système, ainsi que de surveiller l’état de votre système de sécurité Navigation à travers les menus L’état du système s’affiche en haut de chaque écran; l’heure et la date s’affichent en bas de l’écran de sécurité. L’écran de sécurité affiche l’état du système et les « icônes » de sélection. Les pages et options qui s’affichent peuvent légèrement varier selon les dispositifs et services qui sont installés dans le système ou connectés à...
  • Página 4 FONCTIONNEMENT DE L’ALARME INCENDIE ET DE L’ALARME DÉCLARATIONS FEDERAL COMMUNICATIONS COMMISSION (FCC) MONOXYDE DE CARBONE et ISED Votre système d’alarme incendie et votre détecteur de monoxyde de carbone (s’il est L’utilisateur ne doit en aucun cas apporter des modifications à l’appareil, sauf en cas d’autorisation dans les instructions d’installation ou le manuel de l’utilisateur.
  • Página 5: Información General

    Guía rápida del usuario Información general PROWLTOUCH es una pantalla táctil inalámbrica que le permite realizar funciones automáticas y de seguridad, así como monitorear el estado de su sistema de seguridad Navegación de los menús El estado del sistema se muestra a la izquierda de la pantalla, y la hora y fecha se muestran en la esquina superior derecha e la pantalla de seguridad. La pantalla de seguridad muestra el estado del sistema y los “íconos”...
  • Página 6 FUNCIONAMIENTO DE LA ALARMA DE INCENDIO Y MONÓXIDO DECLARACIONES DE ISED Y COMISIÓN FEDERAL DE DE CARBONO COMUNICACIONES (FCC) El sistema de alarma contra incendios y el detector de monóxido de carbono (si está El usuario no debe efectuar ningún cambio ni modificación a los equipos, a menos que las Instrucciones de instalación o el Manual del usuario lo autoricen.
  • Página 7: Informações Gerais

    Guia rápido do usuário Informações gerais A PROWLTOUCH é uma tela Touchscreen sem fio que permite a realização de funções de segurança e automação, além de monitorar o status do sistema de segurança Menus de navegação O status do sistema é exibido ao lado esquerdo da tela e a data e hora são exibidas no canto superior direito da Tela de Segurança. A Tela de Segurança exibe o status do sistema e os “ícones” de seleção. As páginas e opções exibidas podem variar dependendo dos dispositivos e serviços instalados ou conectados ao sistema.
  • Página 8 Qualquer tentativa de realizar engenharia reversa deste dispositivo por decodificação dos protocolos proprietários, descompilação do firmware ou qualquer ação semelhante é estritamente proibida. SUPPORT & WARRANTY This product manufactured by Resideo and its affiliates. The For the latest warranty information, please go to: Honeywell Home Trademark is used under license from https://www.security.honeywellhome.com/hsc/resources/wa/index.html Honeywell International Inc. 2 Corporate Center Drive, Suite 100 For patent information, see https://www.resideo.com/patent...