Uv Lamp Replacement; Impeller Cleaning And Replacement - ICA Turbojet PLUS Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

UV lamp replacement

24. Take down the uv quartz cover
Take out the quartz tube before changing the glass tube; when replacing
the o-ring of the quartz tube, please remember to insert it in the required
position to avoid water leakage.
26. Assemble the quartz cover
In contrast with step 24, assemble
the quartz tube.
Cleaning and replacement of the impeller
29. Take out/set up the impeller
Take out the impeller to clean or change as suggested. Clean the impeller
core with a brush. Replace the impeller, put back the impeller cover. Make
sure the impeller is in its correct position.
27. Assemble the lamp cover
In contrast with step 22, assemble
the quartz tube sleeve.
Impeller
blade
25. Renew the uv lamp
Remove the defective uv lamp,
take down the rubber gasket from
lamp and replace a new uv lamp,
fix the new uv lamp to the power
head.
Impeller cleaning and
replacement:
28. Open the impeller cover
Take down the pump head,
unscrew the impeller cover with
driver.
30. Position the impeller cover and
screw
Shaft
cover
In contrast with step 28, assemble
impeller cover.
21

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido