Flame is obstructed at burner
Appliance
ports
emits a lot of
black smoke
Regulator hose is pinched
when lit
No gas flow
Excess flow safety valve has
Sudden drop in
been activated
gas flow
High or gusting winds
Flame blow
No gas flow
out
Excess flow safety valve has
been activated
Irregular flame
pattern or flame
Burner ports are clogged
does not come
out of the entire
length of the
burner
PLEASE CALL BOND TOLL FREE #1 866 771-BOND(2663)
EXPEDITE YOUR REQUEST FEEL FREE TO EMAIL US
OR VISIT OUR WEBSITE UNDER CUSTOMER SERVICE SUPPORT
IF YOU HAVE QUESTIONS OR CONCERNS
Customer.service@bondmfg.com
www.bondmfg.com
BOND MANUFACTURING CO.
1700 West 4th Street, Antioch,CA 94509
10
Make sure all the gas burner ports are
free of any lava rocks or debris to allow
the gas to flow freely.
Check the regulator hose for bends or
kinks
Check if gas cylinder is empty. If yes,
replace.
Turn the control knob to "OFF", close the
LP tank valve and disconnect the
regulator from the tank. Turn the control
knob to "HIGH". Wait 1 minute. Turn the
control knob to "OFF". Reconnect
regulator to LP tank. Open tank valve
slowly.Light appliance as indicated in
the"To Light"section.
Increase flame to "High"
Check if gas cylinder is empty. If yes,
replace.
See "Sudden drop in gas flow" above
See "Burner will not light using a match"
above.