Cover must be removed when burner is in operation
Firebowl and propane gas cylinder minimum dis-
tance must be over 60"(as per right side photo).
VISUAL CHECK
Prior to each use, check the hose and valve for excessive wear, abrasions or any damage.
LEAK TEST
• Perform a leak test in a well-ventilated area outside.
• Make sure any open flames or cigarettes are extinguished.
• Remove the battery.
• Ensure the burner control knob is in the "OFF" position
• In a bowl, create a soap solution using 1 part water and 1 part liquid detergent.
• Apply the soapy water solution to all connections.
• Open LP tank valve.
• A gas leak will be detected by expanding bubbles originating from the point of the leak.
• If a leak is found at any connection point or if you smell gas, close the tank valve, disconnect
the tank and do not use the appliance until repairs can be made.
TO LIGHT
TIPS: Before Beginning ●Read and understand the instructions thoroughly.
1. Locate the burner control knob and make sure it is in the "OFF"
position.
2. Connect propane (LP) cylinder. (See above pages).
3. Open LP tank valve slowly.
4. Push in igniter button to create sparks at the electrode and hold.
5. Push and turn burner control knob counterclockwise to the "PILOT"
position. Continue to push the control to light the pilot flame.
Note: For initial start or after any cylinder change, hold
Control Knob IN for 2 minutes to purge air from gas lines
before proceeding.
6. After ignition, release the igniter button. Continue to push the
control knob for 45 seconds.
7. If ignition does NOT immediately take place on pilot burner
in seconds,turn the burner control knob to "OFF" ,wait 5
minutes for gas to clear and repeat the lighting procedure.If
pilot still not light,refer to the troubleshooting section.
●Check and make sure that all parts are present.
●For future reference, save this instruction sheet.
7
.