Temperatures And Ambient Humidity; Electrical Specifications; Pump Installation; Installation Into Pipe Lines - IMPPUMPS NMT PLUS COMFORT 15 130 Serie Instalación Y Manual De Operaciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.3

TEMPERATURES AND AMBIENT HUMIDITY

Ambient temperature
[°C]
from 5 to 40
Operation outside recommended conditions may shorten the pump lifetime and void
the warranty.
3.4

ELECTRICAL SPECIFICATIONS

Pump model
NMT Plus Comfort (INOX) 15/90-130
NMT Plus Comfort (INOX) 15/120-130
4

PUMP INSTALLATION

4.1

INSTALLATION INTO PIPE LINES

The pump must be built with the electromotor shaft in a horizontal position (figure 3.1, page 10). The
allowed and forbidden positions are shown in figure 3.2. For some allowed positions the control box
must be rotated which is shown in figure 3.3. When rotating the control box, pump must first be cooled
down and emptied of medium.
Before starting, the pump must be filled with the medium. For appropriate operation, the minimum
pressure of 0,2 bar must be provided on the suction side of pump.
The pump deaerates automatically while working. After installation, let the pump run for a while with
outflows opened. Air in the pump can cause noise. After a short working period the noise will
disappear. Although pump is auto-calibrated meanwhile normal working, it is advised to run the
calibration procedure after pump is deaerated. To do that close all the outflows and turn the pump off
and on again.
In its operational phase the pump heats up or gets heated up by the pumped medium, therefore it
must not be touched – burn hazard!
Pump must not run dry!
Permitted ambient and medium temperature:
Medium temperature [°C]
min.
5
Electrical ratings:
Max Power [W]
60
100
8
Relative ambient
max.
95
Max Current [A]
0,5
0,8
humidity
<95 %
Supply voltage
1~230V, 50Hz
1~230V, 50Hz

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Nmt plus comfort 15/90-130Nmt plus comfort 15/120-130

Tabla de contenido