MODEMISER
3. Operation
The ModeMiser monitors data transmit and receive
lines in the modem line. When data transmission in
both directions stops, a timer begins to count to a
pre-selected time interval. If data does not resume in
either direction before this interval is reached, DTR
to the modem is dropped. This forces the modem to
disconnect the telephone link. You'll have to redial
to establish the link again.
You can adjust the time interval by turning a
recessed screw on the front panel. The standard
time interval ranges from 30 seconds to five minutes.
4. Customizing
The ModeMiser can be easily customized. Call
for technical support and give us your specific
customization requests. For example, the time-
interval selections can be easily adjusted to widely
different ranges—from milliseconds to hours. Up
to five specific switch-selectable time intervals can
be custom-built into the ModeMiser.