Installation
Dirt and Scale Plug Pump and Pipes!
Use New Pipe for Best Results.
Pump
Body
Clean Flow!
Figure 1 – No Dirt or Scale in
Suction Pipe
Figure 2 – Foot Valve Must
Work Freely
No Sags
Sags Allow Air Pockets
If Air Pockets Form, Water Won't Flow.
Keep Pipe Straight and Angled up to Pump.
Figure 3 – No Air Pockets in
Suction Pipe
No Air Leaks
in Suction Pipe.
If Air Flows
Water Won't
Use Teflon™ Tape
Figure 4 – Suction Pipe Must
Not Leak
For parts or assistance, call Simer Customer Service at 1-800-468-7867
Before You Install Your Pump
NOTICE: Pump must not be more than 20' higher than water source.
1. Long runs and many fittings increase friction and reduce flow. Locate
pump as close to well as possible: use as few elbows and fittings
as possible.
2. Be sure well is clear of sand. Sand will plug the pump and void
the warranty.
3. Protect pump and all piping from freezing. Freezing will split pipe,
damage pump and void the warranty. Check locally for frost protection
requirements (usually pipe must be 12" below frost line and pump must
be insulated).
1096 0697
4. Be sure all pipes and foot valve are clean and in good shape.
From
Well
5. No air pockets in suction pipe.
6. No leaks in suction pipe. Seal the pipe joints with
Teflon™ based pipe joint compound.
7. Unions installed near pump and well will aid in servicing. Leave room
to use wrenches.
8.
DO NOT use in a booster application.
1
E. I. DuPont de Demours and Company Corporation, Delaware
NOTICE: Use the installation method which matches your well type.
Cased Well Installation
1100 0697
1. Inspect foot valve to be sure it works freely. Inspect strainer to be sure it
is clean.
2. Connect foot valve and strainer to the first length of suction pipe and
lower pipe into well. Add sections of pipe as needed. Seal the pipe
joints with Teflon™ tape or a Teflon™ based pipe joint compound.
Be sure that all suction pipe is leakproof or pump will lose prime and
fail to pump. Install foot valve 10 to 20 feet below the lowest level to
which water will drop while pump is operating (pumping water level).
Your well driller can furnish this information.
3. To prevent sand and sediment from entering the pumping system,
the foot valve/strainer should be at least 5 feet above the bottom of
the well.
4. When the proper depth is reached, install a sanitary well seal over the
pipe and in the well casing. Tighten the bolts to seal the casing.
5. When using a foot valve, a priming tee and plug as shown in Figure 5
are recommended.
1101 0697
Pipe Joint
Compound Will
Damage Plastic.
1102 0697
Pump body may explode if used as a booster pump.