Setting the first switch-on time (first comfort time)
1.
Set the programming selector to position A1.
2.
Turn the setting knob to adjust the time.
3.
When the required switch-on time is displayed, move the
programming selector to any other position to confirm your setting.
Setting the first switch-off time (first energy saving time)
1.
Set the programming selector to position A2.
2.
Turn the setting knob to adjust the time.
3.
When the required switch-off time is displayed, move the
programming selector to any other position to confirm your setting.
Setting the second switch-on time (second comfort time)
1.
Set the programming selector to position A3.
2.
Turn the setting knob to adjust the time.
3.
When the required switch-on time is displayed, move the
programming selector to any other position to confirm your setting.
Setting the second switch-off time (second energy saving
time)
1.
Set the programming selector to position A4.
2.
Turn the setting knob to adjust the time.
3.
When the required switch-off time is displayed, move the
programming selector to any other position to confirm your setting.
Switch-on and switch-off times are related. When trying to
set a switching time to a time after the next switching time,
NOTE
the latter time will automatically be moved forward
(or backward).
A6V101035986_en--_c
2018-06-21
Setting the comfort temperature
Setting the energy saving temperature
Changing the current setpoint temporarily
Setting the temporary comfort temperature
Changing the batteries
Energy saving tips without sacrificing comfort
Subject to alteration
1.
Set the programming selector to position
2.
Turn the setting knob to adjust the temperature.
3.
When the required comfort temperature is displayed, move the
programming selector to any other position to confirm your setting.
1.
Set the programming selector to position
2.
Turn the setting knob to adjust the temperature.
3.
When the required energy saving temperature is displayed,
move the programming selector to any other position to
confirm your setting.
1.
The current setpoint can be changed temporarily when the
operating mode selector is in the AUTO position and the
programming selector in the RUN position.
2.
Turn the setting knob slightly in either direction to display the
current setpoint, then turn it to adjust the temperature.
3.
This setpoint is maintained until the next switching time. When this
is activated, the hand symbol is displayed.
1.
Turn the setting knob to adjust the desired temperature when the
operating mode selector is set to Comfort mode (temporary
override of Comfort temperature).
2.
The temporary override of the Comfort temperature is cancelled
when the operating mode is changed.
1.
Get 2 new alkaline batteries type AA, 1.5 V.
2.
Within 1 minute: pull out the battery compartment and remove the
batteries, then insert new batteries and replace the battery
compartment.
3.
Make certain the old batteries are disposed of properly, in
compliance with environmental requirements.
·
Never allow room temperatures to exceed 21 C
·
Air out rooms for short periods of time only, but properly, with the
windows wide open
Siemens Building Technologies / HVAC Products
DE
.
EN
FR
IT
NL
.
ES
PT
CS
HU
PL
SV
FI
ZH
TR
EL
RO
DA