RF Thermostat
Code: 0769013
Reference: KT13-W-RF
A. Installation, Mounting:
Caution: Turn off 0769013 and the electrical devices (e.g. heater, cooler)
which will be connected before installation.
It is highly recommended that the installation procedure is processed
by trained personnel.
1.
Installation Location:
a.
For indoor use only
b.
The thermostat (Receiver and Transmitter) should be mounted on an inner wall 1.5m
above the floor in position where it is readily affected by changes of the general room
temperature with freely circulating air. The mounting place must be clean and dry
indoor places. Prevent direct exposure to sunlight; dripping or splashing area. Do not
place this unit at a location where air circulation is low, or where it has great
temperature changes (e.g. near door). Do not place the thermostat near heat/cool
generating sources.
2. Wiring for Receiver:
Caution: Turn off the electrical devices and receiver before wiring.
There are 2 wiring terminals (N, L and 1, 2) at the bottom of 0769013 (Receiver).
Connect heater /cooler to the "1" and "2" terminals and connect 240Vac to "N" and
"L".
Wire the correct cables to the terminal block according to the circuit diagram which is
attached inside the thermostat top cover.
For installation, no metal conduits or cables provided with a metal sheath in the wall
box.
Push all cables back into wall prior to fixing to avoid trapping wires.
It is recommended that a 10A fuse be fitted.
RT48 Receiver wiring
3. Mounting:
Using the accessory screws and wall anchors provided, mount 0769013 with the
key-hole at the back. The Transmitter and receiver should be mounted on the wall
Install or replace the battery for transmitter:
Caution: Replace only with the same or equivalent type of batteries. Do not dispose
the used batteries with household waste. Refer to your local area for the proper
disposal.
1. Pull out the battery drawer
2. Place the new batteries according to the marking on the battery drawer.
3. Dispose the old batteries properly.
4. Slide the battery drawer back to its position.
5. Check if the thermostat works properly or not.
6.
Press "RST" if necessary.
Use a flat screwdriver
to press on the gap at
both sides to detach
the front shell.
B. Start/Reset:
1. After wiring and mounting, switch off all the connected devices. Place 2 new AAA 1.5V
alkaline batteries according to the polarities marked.
LCD display will be switched on.
2. Press 'RST' to reset. The 0769013 will be ready to control the heater / cooler.
3. Switch ON the heater / cooler and Receiver. The heater / cooler will remain OFF until
transmitter activates the output ON with
C. Normal Time Setting Mode:
1. Press <
>, the Day of Week (1-7) will flash, press < >, < > to select the current Day
of Week.
2. Press <
>, the Hour will flash, press < >, < > to set the Hour.
3. Press <
>, the Minute will flash, press < >, < > to set the Minute.
4. Press <
> will jump back to the step 1.
5. Press <
> to confirm the settings and return to Normal Mode.
Or transmitter will auto-return to normal mode after 10 seconds.
D. Set Program:
1. Press <PRG>, the hour will flash, press < >, < > to change the hour setting.
2. Press <PRG>, the minutes will flash, press < >, < > to change the minutes setting.
3. Press <PRG>, temperature will flash, press < >, < > to change the setpoint.
4. Press <PRG> to set the next program.
5. The program setting sequence is as below:
Mon~ Fri (P1 P2 P3  P4P5P6) Sat (P1 P2 P3  P4P5P6)
Sun (P1 P2 P3  P4P5P6)...
6. Press <
> to exit the program mode setting and return to the normal mode.
Or transmitter will auto-return to normal mode after 10 seconds.
E. Temporary / Permanent Override Mode:
There are two modes in the override mode (Temporary override and Permanent override
mode). Press
The sequence is as below:
Normal Temporary Override  Permanent Override Normal...
Selecting the Temporary/ Permanent Override Mode
<
> to
1. Press
displayed.
<
>
2. Press
mode.
icon will be displayed.
<
>
3. Press
Review and Adjust the Override Temperature:
1. Press < >/< >, the Override temperature is shown.
2. Hold the < >/< > for 2 seconds, the Override temperature will flash.
3. Press < >/< > to adjust the Override temperature.
4. Press <
> to exit the Override temperature setting.
Or transmitter will auto-return to normal mode after 10 seconds.
0769013 Transmitter installation
Temporary Override Mode:
Figure 1
Temporary Override mode maintains until next program time is met.
Permanent Override Mode:
The room temperature will be maintained at the Override temperature until Override
mode is released. Press <PRG> to release the Permanent Override mode.
RST
F. Control Off / Sleep Mode:
1. Press the <
Normal Mode  Sleep Mode  Control Off ModeNormal Mode ...
2. Press any other keys to exit the control off / Sleep mode and return normal mode.
/
displayed on LCD.
<
>
to select the override mode.
change the mode from normal to Temporary Override.
again, the mode changes from Temporary Override to Permanent Override
once, the mode changes from Permanent Override to normal mode.
> to select the sleep mode and control off mode. The sequence is as below:
Sleep Mode:
At sleep mode, <
> icon is displayed. Transmitter stops measuring and
displaying the temperature. Only the current time is shown.
The heater / cooler is turned off, irrespective of the current control setting
temperature.
Control Off Mode:
The LCD is fully turned off. The heater / cooler is switched off, irrespective of
the current control temperature setting.
G. Jumper Selection:
Delay / No Delay jumper:
Heater
No delay
10sec
Delay
4mins
Choose the Delay option if compressor heat is connected.
12-hours / 24-hours mode jumper:
When the 12-hours option is selected, the time is shown in 12-hours mode.
Otherwise, the time is shown in 24-hours mode.
Heater / Cooler jumper:
Select the heater option when a heater is connected to receiver. Select the cooler
option when a cooler is connected to receiver.
H. Address Setting:
In transmitter and receiver, there are dip switches to select the addresses. The
receiver ignores the message which is sent by the transmitter with different
address setting.
I. Low Battery:
If Battery is LOW,
will be flashing. The old batteries must be replaced
with new one immediately.
J. Defrost Function:
Defrost function is activated with
below. Output will be forced to ON @ Heat & OFF @ Cool.
K. Specification:
1. Temperature measurement:
2. Accuracy:
3. Temperature control range:
icon will be
4. Terminals:
5. Classification of control:
6. Purpose of control:
7. Electronic control:
8. Transmitter — Battery:
9. Receiver — input voltage:
10. Receiver — output voltage:
11. Operating temperature:
12. Storage temperature:
13. Sensing Element:
TEMPER ENERGY INTERNATIONAL S.L.
Polígono industrial de Granda, nave 18
33199 • Granda - Siero • Asturias
Teléfono: (+34) 902 201 292
Fax: (+34) 902 201 303
Email: info@grupotemper.com
www.grupotemper.com
Cooler
4mins
4mins
displayed when temperature is 5°C or
0 - 40°C (0.5°C/step)
± 0.5°C
5.0 - 35.0°C (0.5°C/step)
2
Use 2.5mm
flexible conductor for
connection
Class II
Micro-disconnection on operation
Type 2.B
2 x 1.5V AAA alkaline battery
240Vac
24..240VAC 50/60Hz 16 (3)A max
0 - 50°C
-10 - 60°C
103AT-2B NTC thermistor
140828

Publicidad

loading

Este manual también es adecuado para:

0769013