Bristle Blaster
Pneumatic
9.
SERVICE INSTRUCTIONS
1. The tool is to be serviced exclusively by qualified staff members or by the dealer who has sold it. Repair or
servicing by unqualified personnel may result in injuries and/or damage to the tool.
2. Only original spare parts are to be used for the servicing of the tool. If parts that are not approved are used or
maintenance instructions are not followed, the warranty will be rendered void and there may be a risk of injury.
10.
TROUBLESHOOTING
Fault
Cause
Belt does turn or
Compressor is not operating
turns slowly
Filter or compressed air hose blocked
Insufficient compressor pressure
Inadequate compressor performance
Compressed air hose too long
Diameter of compressed air hose too small
Compressed air motor insufficiently
lubricated
Valve or valve sealing ring faulty
Unusal sound
Mechanical parts insufficiently lubricated
Bristle Blaster
faulty
Water entering the machine via the
compressed air supply
Heavy vibration of
Adaptor System is not fastened correctly
the rotating belt
Foreign body jammed between spindle and
Adaptor System
Adaptor System worn
Bristle Blaster
Adaptor System
Screw not tightened or serrated lock washer
comes undone in
not used
operation
Screw / serrated lock washer worn
®
Belt or other machine parts
®
Belt faulty
Operating instructions
Solution
Switch on or check compressor
Clean compressed air line
Increase compressor pressure
Use more powerful compressor
Use compressed air hose of suitable length
Use compressed air hose of suitable size
Add a few drops of oil to the compressed air
connection
Servicing by qualified engineer
Servicing by qualified engineer
®
Fit new Bristle Blaster
qualified engineer
Servicing by qualified engineer
Re-fit Adaptor System
Remove object and re-fit
Use new Adaptor System
®
Fit new Bristle Blaster
Use serrated lock washer and tighten screw
Use new screw / serrated lock washer
GB/US
Belt / servicing by
Belt
21