Section 3: Operation
Operation and Use Questions
Call Generac Customer Service at 1-888-GENERAC (1-
888-436-3722) with questions or concerns about unit
operation and maintenance.
Before Starting the Unit
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
Familiarize yourself with the controls and features of the
unit before operating. See
Operating Zone
•
See
Figure
3-1. Stand in operator areas (A) when-
ever operating this unit.
•
Stay in the operator areas at all times when the
ram is in motion.
•
Never place any part of your body into a position
that causes an unsafe operating condition.
A
Figure 3-1. Operator Zone
Owner's Manual for 10 Ton Kinetic Spliter
(000100a)
Components and
Controls.
A
010950
Starting the Motor
1. Position the unit on a flat, dry surface and chock
the wheels or screw down the frame stand to pre-
vent the unit from moving during use.
2. Plug the unit into a properly grounded 20, GFCI
protected outlet.
3. See
Figure
3-2. Push toggle switch (A) into the ON
position
Stopping the Motor
See
Figure
3-2. Push toggle switch (A) to OFF position.
Resetting the Circuit Breaker
See
Figure
3-2. If the motor will not run when the power
switch is turned on and power is connected to the
machine, the circuit breaker switch may need resetting.
Push circuit breaker switch (B) to reset.
Figure 3-2. ON/OFF Switch and Circuit Breaker
Handling Wood
WARNING
Equipment damage. Do not overload the log splitter.
Do not attempt to split logs beyond the units
capability. Doing so could result in serious injury or
equipment damage.
WARNING
Personal injury. Do not reach or step across the
beam while the log splitter is running. Doing so
could result in death or serious injury.
Operation
A A
B
010951
(000439)
(000442)