All manuals and user guides at all-guides.com Installation manual Daikin Altherma low temperature monobloc control Installation manual English Daikin Altherma low temperature monobloc control box EKCB07CAV3...
Página 2
All manuals and user guides at all-guides.com 3P4039882A...
Digital files on http:// equipment 1 About the documentation www.daikineurope.com/ About this document..............supportandmanuals/ productinformation/. 2 About the box Control box ................Latest revisions of the supplied documentation may be available on the regional Daikin website or via your dealer. 2.1.1 To remove the accessories from the control box ..The original documentation is written in English. All other languages 3 Preparation are translations. Preparing installation site ............3.1.1 Installation site requirements of the control box..Preparing electrical wiring ............3.2.1 Overview of electrical connections for external and About the box internal actuators ............4 Installation Control box Opening the units ..............
100 mA WARNING Optional equipment The screws are delivered with toothed lock washers. Preferential kWh rate ALWAYS use toothed lock washers, also when the screws power supply (voltage need to be replaced. Failure to follow this warning may free contact) result in electric shock. Backup heater kit thermistor Backup heater kit thermal protector Backup heater kit 2 (3V3) connection (from 3 (6V3, 6W1, control box) 9W1) Installation manual EKCB07CAV3 Daikin Altherma low temperature monobloc control box 4P4040751 – 2015.03...
Equipment complying with EN/IEC 61000312 (European/ International Technical Standard setting the limits for harmonic 2 Fix the cable with cable ties to the cable tie mountings to currents produced by equipment connected to public lowvoltage ensure strain relief and to make sure that it does NOT come in systems with input current >16 A and ≤75 A per phase.). contact with sharp edges. CAUTION Do NOT push or place redundant cable length in the unit. EKCB07CAV3 Installation manual Daikin Altherma low temperature monobloc control box 4P4040751 – 2015.03...
When NOT control box terminals X2M/20+21. interface cable to Be careful NOT to distort the shape connecting a user control box of the backside of the user interface interface to the Fix the cable with cable ties to the terminals by overtightening the mounting control box, do NOT cable tie mountings. X2M/20+21. screws. remove the plugs from the holes in the front plate. Route the cable from the righthand side of the terminals, fasten it to the cable tie 2× mountings and route it through the hole of the low voltage 2× wiring. Connect as shown in 4A. Connect as shown in 4A, 4B, 4C or 4D. Reconnect the faceplate to the wall plate. a Main user interface Be careful NOT to pinch the wiring when connecting the front panel to the control box. Installation manual EKCB07CAV3 Daikin Altherma low temperature monobloc control box 4P4040751 – 2015.03...
1× 1× 4C From the top 4D From the top centre 1× 1× Notch this part for the wiring to pass through with nippers etc. Secure the wiring to the front part of the casing using the wiring retainer and clamp. Starting up the system For instructions on how to configure and commission the system, and hand it over to the user, refer to the installation manual of the outdoor unit. EKCB07CAV3 Installation manual Daikin Altherma low temperature monobloc control box 4P4040751 – 2015.03...