3
2
3
1
4
2
is connected to the system with a single non polari-
zed twisted pair.
It can be used in wall-mounted or tabletop ver-
sions, depending on the mounting it is teamed
with.
It features the following controls and indicators (fig. 1):
ON/OFF-brightness control
(side thumbweel D) (
Entry panel activation/selection (
1
Auxiliary control 1 (
Auxiliary control 2 (always enabled)
Door-lock release control (
(
1
) The unit can only be switched on and conse-
quently connected to the entry panel if the system
is not engaged with other calls.
4
(
2
) Auxiliary control 1 and the door-lock release
control can only be used via the monitor when the
unit is switched on.
WARNINGS FOR THE USER
- Do not open or tamper with the unit: high volt-
SW1
age inside.
- Be careful not to knock or bang the unit as
this might break the picture tube resulting in fly-
ing glass.
- Always use the services of skilled personnel to
remedy faults, make changes or service the
installation's units (power supplier etc.).
Call note
Remove the SW1 jumper in the event the volume of
the call note is to be attenuated, figure 3-5.
Personal door-bell
F1
The unit is fitted with a differentiated call input for
calls from the occupant's door, producing a contin-
uous note lasting 2 s.
5
Entry panel selection in installations with a
number of entry panels
To use this function, turn on the monitor by press-
ing the button entry panel connection. Next, press
the same button again to select the entry panels.
NOTE. If a call is made from the entry panel during
selection, the process is aborted.
If said call is being made to the user making the
selection, the monitor features the image from the
E
entry panel the call is made from.
If the call is made to a different user, the image on
the monitor disappears.
Resistive load termination
The unit features a jumper SW3, located at the
2
back (fig. 2) for the impedance terminating the sig-
nal line. Remove the jumper if the line continues
towards other user extensions.
Technical features
• Video standard: CCIR (EIA).
6
• Horizontal frequency: 15,625 Hz (15,750 Hz).
• Picture tube: 5" (12.5 cm) at 90°.
• Power source: local 12 to 16V AC or 14 to 18V DC,
centralized 14 to 18V DC.
F
• Current demand: max. 650mA (2mA on stand-by).
• Bandwidth response at –3dB: 5 MHz.
• Automatic gain control for input signal: 46 dB.
• Call signal: two-tone lasting 30 s.
• Working temperature range: 0 °C to +35 °C.
• Dimensions: 192x220x112 mm.
5
Safety fuse F1 type T 1A is located on the mount-
ing's printed circuit (fig. 3-5).
(Fuse: F = fast-blow; T = delayed).
Fastening the monitor onto the wall mounting
Make sure locking mechanism C is pushed to the
right (open setting,
Place the monitor on the wall mounting B, push it
down onto the mounting and then secure it in place
with mechanism C.
Follow the steps in the order illustrated by the
7
arrows in fig. 4.
)
1
1
)
)
2
)
2
fig. 3).
Fastening the monitor onto the table-top mount-
ing
Insert element E in the relevant slot located on the
back of the monitor and secure in place with the
screw supplied (fig. 6).
Apply table-top mounting F, attaching the top first
(fig. 7) and then securing it in place on the monitor
with the two long screws supplied (fig. 8).
INSTALLATIONS-
D
ANLEITUNG
ACHTUNG! NUR FÜR INSTALLATEUR
Diese Anleitungen sind der Innensprechstelle
beizufügen.
MONITOR MIT HÖRER VM/300
Monitor mit Mitseh- und Mithörsperre für den mit
System 300 kompatiblen Audio-, Video- und
Datenempfang geeignet. Das Gerät ist an die
Anlage über eine ungepolte Telefonschleife allein
verbunden.
Je nach verwendeter Halterung sowohl in der
Wand- als auch Tischausführung verwendbar.
Mit folgenden Steuerfunktionen und Meldungen
(Abb. 1) ausgestattet:
An/Aus - Helligkeit (seitlich angeordneter
Knopf D)
Einschaltung und Auswahl der Außenstation (
Zusatzsteuerung 1 (
2
)
Zusatzsteuerung 2 (stets eingeschaltet)
Türöffnertaste (
2
)
(
) Die Einschaltung des Geräts und der ansch-
1
ließende Anschluss an die Außenstation sind nur
möglich, wenn die Anlage nicht durch andere
Verbindungen besetzt ist.
(
2
) Die Zusatzsteuerungen 1 und die Türöffner-
funktion sind nur bei eingeschaltetem Gerät über
den Monitor einschaltbar.
HINWEISE FÜR DEN BENUTZER
- Bitte Gerät nicht öffnen oder aufbrechen;
hohe Spannung vorhanden
- Zur Vermeidung eines Bildröhrenbruchs mit
demzufolgenden Glasscherben Stöße und
Schläge am Gerät vermeiden
- Sich
bei
Störungen,
Änderungen
Reparaturen an den Anlagengeräten (Netzgerät,
etc.) nur an Fachpersonal wenden.
Rufton
Falls man die Lautstärke des Ruftons herabsetzen
möchte ist die Überbrückungsklemme SW1 abzu-
nehmen (Abb. 3-5).
Etagenruf
Das Gerät verfügt über einen Eingang für die
Anrufunterscheidung von der Etage mit einem 2 s
langen Dauerton.
Auswahl der Außenstation bei Anlagen mit
mehreren Eingängen
Zur Einschaltung dieser Betriebsart ist die Taste
Außenstation einschalten zu betätigen, um den
Monitor einzuschalten und danach dieselbe Taste
zwecks Auswahl der Außenstationen zu drücken.
ANMERKUNG. Ein eventuell von der Außenstation
kommender Ruf unterbricht den Auswahlvorgang
und, falls der Ruf für die gleiche Innensprechstelle
bestimmt ist, erscheint auf dem Bildschirm das Bild,
das an der Außenstation, von der der Ruf erfolgte,
aufgenommen wurde. Sollte der Ruf dagegen für
eine andere Innensprechstelle bestimmt sein, so
verschwindet das Bild vom Bildschirm.
Schließwiderstand
Auf der Geräterückseite befindet sich eine Über-
1
)