Technical Data - Renfert SILENT TC Manual De Instrucciones

Ocultar thumbs Ver también para SILENT TC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
Trouble
Suction starts even
though the electrical ap-
EN
pliance connected to the
socket is not being used.
Suction does not stop
when the electrical appli-
ance is switched off.
Suction does not start
even though the electrical
appliance connected to
the socket is in used.
Fuse triggers when a con-
nected electrical device is
switched on.
The suction stops abrupt-
ly in automatic or continu-
ous operation and the as-
sociated displays (20 / 22,
Fig. 2) are still on.
After the suction motor
was changed, the suction
unit stopped functioning
or stops suddenly.
8

Technical Data

Item no.
Nominal voltage
Permitted voltage:
Mains frequency:
Suction turbine power: *)
Max� connection value of the appliance socket: *)
Total connected power: *)
Mains input fuse:
LpA * *) (at max. flow):
Ø suction support:
- inner
- outer
max. Volume flow:
Vacuum pressure, max�:
Fine filter:
- Filter surface approx�
- Filter qualitly
Fill level dust drawer, approx�:
Weight (empty), approx�:
Dimensions (width x height x depth):
*) Performance values at nominal voltage
**) Noise level according to EN ISO 11202
Reason
• The automatic switch-on function
has been set too low�
• The automatic switch-on function
has been set too low�
• The automatic switch-on function
has been set too high�
• Power consumption of the connect-
ed device too high�
• Suction turbine is overheated�
• Suction turbine is defect�
• The plug from the suction motor is
not sufficiently clicked in place.
• Setting the automatic switch-on (see chapter 5�5�3)�
• Setting the automatic switch-on (see chapter 5�5�3)�
• Setting the automatic switch-on (see chapter 5�5�3)�
• Observe the maximum connection value (see chap-
ter 8)�
• Switch off the device and leave to cool for at least
60 min�
• Check whether suction tube is blocked, eliminate block-
age�
• Switch the device off and then on again to perform a
filter cleaning.Change fine filter (see chapter 6.3) if filter
cleaning does not improve the performance�
• Change Suction turbine�
• Connect the suction motor plug correctly�
Ensure that the plug is fitted correctly and clicked into
place by pulling it�
2935 0000
230 V
220 - 240 V
50 / 60 Hz
850 W
2000 W
2850 W
2 x 15 A(T)
54,3 dB(A)
45 mm [1�77 inch]
50 mm [1�97 inch]
3980 l/min [2�34 ft³/s]
281 hPa
[4�1 psi]
0�9 m² [1390 sq inch]
Class M according to EN 60335-2-69
7 l [1�85 US gal]
275 x 535 x 540 mm
[10�8 x 21�1 x 21�3 inch]
- 16 -
Solution
22,0 kg
[48�5 lbs]

Publicidad

Tabla de contenido

Solución de problemas

loading