4.
Remarks in respect of the determined use
4.1 Operation of the tool
The pressing cycle is started by actuating the trigger (page 1, pic. 1.7). The pressing cycle is characterized by the
closing motion of the jaws. Due to the linear movement of the rollers on the piston the jaws close scissors like.
Attention
A necessary condition for a permanently leaking free connection is that the pressing cycle has to be com-
pleted and the jaws are closed.
Attention
The pressing process can be interrupted at any moment by releasing the trigger.
Attention
For information concerning the suitability of the tool with regard to dimension and fi eld of application (gas/
water/heating etc.), please refer to the documentation of your system manufacturer.
Attention
The user has to check by optical means whether the pressing jaws are completely closed.
Attention
If a pressing cycle has been interrupted the fi tting has to be either dismantled or pressed a second time.
Attention
Do not operate the tool without jaws.
Achtung
For your own safety please observe all national and European safety regulations.
The user needs to make sure that the pressing jaws are completely closed and that there are no foreign objects (e.g.
plaster or stone fractions) between the pressing jaws.