Replacement Parts; Performance Data; Operating Requirements - Culligan SY-1000S Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Replacement Parts

1 144842 Head Assembly
2 155785 1000R Filter Cartridge
3 155901 750R Filter Cartridge
4 144846 Hardware Kit
5 151242 Lead-Free Faucet (FT-10)
1
6 Clear
/
–inch Tubing
4
7 143431 Water Supply Adapter
4
3
2
6
For replacement parts, contact your nearest retailer or call
Culligan Consumer Services at 1-888-777-7962.
Maintenance
Contact your area retailer or local water treatment professional for replacement
cartridge pricing.
Suggested Retail Price for Replacement Filter Cartridges: 1000R: $29.99, 750R:
$10.99
1
7
5

Performance Data

Model SY-1000S
Important Notice: Read this performance data and compare the capabilities of
this system with your actual water treatment needs. It is recommended that,
before installing a water treatment system, you have your water supply tested to
determine your actual water treatment needs.
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42 and 53.
1000R Cartridges
Substance
Influent Challenge
Max. Permissible Product
Concentration
Water Concentration
Standard 42 Aesthetic Effects
Chlorine
2.0 mg/L±10%
Particulates
at least 10,000
(0.5–<1m)
particles/mL
Class I
Standard 53 Health Effects
Cysts†
Minimum 50,000/L
Turbidity
11±1 NTU
Lead (pH 6.5)
0.15 mg/L±10%
Lead (pH 8.5)
0.15 mg/L±10%
Atrazine
0.009 mg/L ± 10%
Lindane
0.002 mg/L ± 10%
Flow Rate=0.5 gpm (1.89 Lpm)
Capacity=500 gallons (1892 L) or 6 months
† Based on the use of Cryptosporidium parvum oocysts.
Testing was performed under standard laboratory conditions, actual performance may vary.
This system has been tested according to NSF/ANSI 42 for the reduction of the substances listed below. The concentration of the indicated substances
in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 42.
750R Cartridges
Substance
Influent Challenge
Max. Permissible Product
Concentration
Water Concentration
Standard 42 Aesthetic Effects
Chlorine
2.0 mg/L±10%
Flow Rate=0.75 gpm (2.8 Lpm)
Capacity=2500 gallons (9460 L) or 12 months
Testing was performed under standard laboratory conditions, actual performance may vary.
Test Conditions:
Flow Rate
= 0.5 gpm
Inlet Pressure
= 60 psi (4.1 bar)
pH
= 7.5 ± 1
Temperature
= 68º F ± 5º F (20º C ± 2.5º C)

Operating Requirements:

Pressure
= 30-125 psi (2.1-8.62 bar)
Temperature
= 40º-100º F (4.4º-37.7º C)
Turbidity
= 5 NTU Max
WARNING:
Do not use with water that is microbiologically unsafe or
unknown quality without adequate disinfection before or after the system. Systems
certified for cyst reduction may be used on disinfected waters that may contain
filterable cysts.
NOTE: Substances reduced are not necessarily in your water. Filter must be
maintained according to manufacturer's instructions, including replacement of
filter cartridges.
5
Reduction
Minimum
Requirements
Reduction Reduction
≥ 50%
≥ 85%
99.95%
99.99%
0.5 NTU
99.6%
0.010 mg/L
99.3%
0.010 mg/L
98%
0.003 mg/L
97.7%
0.0002 mg/L
97.5%
Reduction
Minimum
Requirements
Reduction Reduction
≥ 50%
Average
99%
99.8%
99.99%
99.7%
99.3%
98.6%
97.7%
97.5%
Average
87.8%