SP01 CONTROL UNIT
GB
WARNING! The SP01 control card directly supplies the 24V system through output 5-6 therefore the 230V power
supply of the automation must be disconnected.
Connections:
- terminals 1-2 panel input (polarity must be respected)
3 - 4 battery input CHECK POLARITY
9 - 11 command output (to be connected to the command input e.g. Step-step) that repeats the signal of the first radio channel
and/or P1 wire control (terminals 12-14)
Optional connections:
9 - 10 auxiliary command output (to be connected for example to the "pedestrian opening") that repeats the signal of the second
radio channel and/or P2 wire control (terminals 12 13)
12 - 13 - 14 inputs for wire controls
15 - 16 input for off control (see "SP01 Functions")
17 - 18 input for receiver aerial (see OC2 receiver instructions)
7 - 8 24V output (max 100mA) for one buzzer (and/or one LED) to indicate the state of the system.
SP01 Functions
Automatic switching off with gate open indicator.
This option optimises the length of time the system is switched on and consequently increases the autonomy of the battery.
Place dip-switch 1 onto ON and connect the "gate open indicator" signal to input 15-16; when the gate is completely closed and
the indicator is off the SP01 control unit will switch off the power supply. The TL trimmer adjusts the maximum on-time beyond
which the SP01 will switch off in any case.
Switching off with timer
Place dip-switch 1 on OFF and adjust the on time using the TL trimmer.
The time is recharged using commands P1 and P2 and/or the remote control.
Battery level indicator
The batteries connected to the Sun Power are constantly monitored by the SP01 control unit and their state is indicated by the
LEDS LD1 (green) and LD2 (red). For an acoustic signal connect a buzzer to terminals 7-8 (see "optional connections")
1 beep and flashing green LED = charged batteries (voltage over 25V)
2 beeps and flashing green and red LEDs = batteries being charged (voltage between 21 and 25V)
3 beeps and flashing red LED = flat batteries (voltage below 21V) and system blocked
Indicator of charge from panel
When the output of the SP01 control unit has been activated the green LED not only signals the battery charge level but also
whether the panels are supplying sufficient voltage to charge the battery.
The test can only be carried out when it is sunny (illuminated panels) and is useful to check the panel connections. Test:
- during the pauses of the battery indicator the green LED (LD1) flashes fast for 1-2 second: system OK
- the green LED does not flash: check panel connections and polarity.
STEUERUNG SP01
D
ACHTUNG! Die Steuerkarte SP01 speist die 24V-Anlage direkt durch den Ausgang 5 - 6, somit muss die 230V-Speisung
der Automatisierung abgetrennt bleiben.
Anschlüsse:
- Klemmen 1 2 Eingang Kollektoren (die Polarität einhalten)
3 - 4 Batterieeingang DIE POLARITÄT BEACHTEN
9 - 11 Steuerausgang (an den Steuereingang anzuschließen, z.B. Schrittbetrieb), somit wird das Signal des ersten Funkkanals
und/oder der Kabelsteuerung P1 wiederholt (Klemmen 12 - 14).
Zusätzliche Anschlüsse:
9 - 10 zusätzlicher Steuerausgang (zum Beispiel an den Eingang „Fußgängeröffnung" anzuschließen); dieser wiederholt das
Signal des zweiten Funkkanals und/oder der Kabelsteuerung P2 (Klemmen 1213)
12 - 13 14 Eingänge für Kabelsteuerungen
15 - 16 Eingang für die Ausschaltsteuerung (siehe „Funktionen SP01")
17 - 18 Eingang für Empfangsantenne (siehe Anleitungen Empfänger OC2)
7 - 8 Ausgang 24V (max. 100mA) für einen Summer (und/oder eine Led) zur Anzeige des Anlagenzustands.
Funktionen SP01
Automatisches Abschalten mit Meldeleuchte Tor geöffnet
Diese Option optimiert die Einschaltzeit der Anlage und erhöht somit die Autonomie der Batterien.
Den Dip-Switch 1 auf ON stellen und am Eingang 15-16 das Signal der „Meldeleuchte Tor geöffnet" anschließen, wenn das Tor
das Schließen vervollständigt und die Meldeleuchte erlischt, stoppt die Steuerung SP01 die Speisung. Der Trimmer TL regelt
12