Wiring; Wiring Diagram - Dimplex BLF7451 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Fireplace Installation

Wiring

WARNING: To reduce the risk
of fire, electric shock or injury to
persons, always use a licensed
electrician.
WARNING: Ensure that the circuit
on which the fireplace is to be
installed has the power cut off at
the service panel until installation
is complete.
1. Carefully remove the electrical
cover bracket from the back of the
fireplace by removing the three
retaining screws. (Figure 2)
2. Leaving a minimum of 3 in. (7.6
cm) of slack, route the power
supply through a cable clamp
(not included) and the hole in the
electrical cover bracket.

Wiring Diagram

SWITCH BOARD
LED STRIPS
(RGB) - MEDIA
DISPLAY / CONTROL BOARD
8
RELAY BOARD
LED STRIPS
(RGB) - FLAME
FLICKER MOTOR
M
THERMISTOR
AC/DC
ADAPTER
FLAME LED STRIPS (AMBER)
3. Remove the two covers off of the
unit at the front to access the wire
connections. (Figure 3)
Figure 2
Screws
Electrical Cover Bracket
M
BLOWER MOTOR
ELEMENTS
THERMAL
LED DRIVER
BOARDS
CUTOUT
www.dimplex.com

Publicidad

Tabla de contenido
loading

Tabla de contenido