1 Overview
This product is an 8 Input/8 Output device that allows the ACTpro controller t o be used in applications
where signalling to other equipment is required. E xamples of this are elevator control, alarm systems,
CCTV switching and general monitoring.
A maximum of 4 Input/Output Modules may be connected to any single controller, g iving control of up to 32
relays and 32 inputs per ACT4000/ACT1520.
See also:
http://van.fyi?Link=ACTproIOM
l
1.1 Features
8 form C relays
l
8 supervised inputs
l
Tamper protection
l
3 status LEDs
l
Timer for each output
l
Input timer
l
Output switched ON/OFF by log event, input or timezone
l
ACTEnterprise support
l
1.2 ACTEnterprise support
Named inputs and outputs
l
Inputs and outputs Logged
l
Normally open/closed
l
Active on timezone
l
Active on event, user, door or user group
l
Active on input on/off
l
Active on output on/off
l
1.3 Technical specification
Voltage
Current Consumption
Communications
Operating Temperature
Mounting
Installation
Weight
Dimensions
© Vanderbilt 2018
12V DC
250mA
RS485 to ACTpro controller
-10°C to +50°C / +14°F to +122°F
Surface
Indoors
500g / 1.102lb
236mm wide, 165mm high, 55mm deep / 9¼" wide x 6½" high x 2¼" deep
EN – 5