Continuation of installation:
Install the 2 iron grips onto the cable next to the OKU-STB1205 and the OKU-
BUF1205. The exact location is mentioned on the side and top view of the installation
instructions.
Install the 3 iron grips as mentioned on detail 244.
Stretch out the cable: please sit on seat and travel 4 times back and forth ( load of
approx. 90 kilos)
The cable will stretch out and the stations will adapt to the circumstances. Please
tension the cable as described above mentioned.
Control phase: please sit on cable and travel 1 time back and forth and make sure that
the distance is 67 cm between bottom side of the seat and ground level in a non
loaded situation.
In a loaded situation with a weight of 130 kilos the minimum distance between
bottomside seat and the ground level should be 40 cm.
Distance of the topside of the seat until bottom side of the cable has to be a minimum
of 180 cm. To reach this distance you can shorten the chain.
Tension the cable again if necessary.
Finalize installation:
The rest length of the cable can be removed. Please add tape to the cable (5 times) at a
distance of 40 cm of the third iron grip. (OBV-5412000).
This avoids that the cable will fray. Please shorten the cable in by means of an
abrasive cutting-off wheel.
Finally the covering caps OME-2226475 can be put on.
Enclosure: detail 243, 244 and 1885.
Zaltbommel, 01-01-2010