18"
(45.7 cm)
15-7/8"
(40.3 cm)
4-3/16"
(10.6 cm)
Product Information
Drop-in whirlpool
Integral flange, left drain
Integral flange, right drain
Required accessories:
Jet trim kit
Fixture*:
basin area
Bathing
45" (114.3 cm) x
well
25" (63.5 cm)
water depth
To
17-3/4" (45.1 cm)
overflow
* Approximate measurements for comparison only.
Pump
Heater
1.5 hp
1.5 kW
* Approximate measurements for comparison only.
Drop-in cut-out
64-1/2" (163.8 cm) x 34-1/2" (87.6 cm)
Cut-out for undermount
1019476-1-C
K-809-H2
66" (167.6 cm)
2-7/8" (7.3 cm)
1/2" (1.3 cm)
3" (7.6 cm)
K-809-H2
shown
K-809-LH
not shown
K-809-RH
not shown
K-9698
top area
weight
58" (147.3 cm) x
510 lbs
29" (73.7 cm)
(231.3
kg)
capacity
97 gal (365.2 L)
V
A*
240
11
K-587 template
No change in measurements if connected with drain
illustrated. (K-7145 or K-7145M)
Pump/Control Access
34" (86.4 cm) W x 15" (38.1 cm) H
3/4"
(1.9 cm)
24"
(61 cm)
Required Electrical Service
Dedicated circuit required, protected with a Class A
Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage
Circuit-Breaker (ELCB):
Pump/control
208-240 V, 20 A, 50/60 Hz
Locate the outlet behind the whirlpool and within 24"
(61 cm) of the pump.
Installation Notes
Install this product according to the installation guide.
Cast iron whirlpools are extremely heavy, making some drop-in
installations difficult. Splitting the deck/surround is recommended
if installing into a deck.
Floor support under whirlpool must provide for a minimum of
2000 lbs (907.2 kg).
Hot water supply should be 70% of capacity or greater.
Installations will vary.
Fixture conforms to ASME Standard A112.19.1M. All dimensions
are nominal.
2
36" (91.4 cm)
1-1/2" OD
Kohler Co.

Publicidad

loading

Este manual también es adecuado para:

K-809-h2