iCLASS SE® Biometric/
iCLASS SE Display Reader
1
Mounting
ATTENTION
Observe precautions for handling ELECTROSTATIC SENSITIVE DEVICES
Reverse Configuration
Rotating the backplate 180° allows for placing the LCD display on left and the reader on right.
See PLT-02969 - Alternate Reader Assembly for instructions, before proceeding to Step 2: Wiring.
Scan the QR Code or visit
2
Wiring
Beeper
GPIO1
GRN LED
GP102
GND
OC/TMPR
+VDC
DATA1/CLK
DRAIN
DATA2/DATA
RED
GPIO3
HOLD
GPIO4
P1
P2
Terminal Reader
(Terminal block and
module position varies)
All manuals and user guides at all-guides.com
RKL40, RPKL40, RKLB40
SRD MODEL: RKCL40E, RPKCL40E, RKCLB40E
Junction box
not included
Install gasket
Wall backplate
www.hidglobal.com/PLT-02969
PIGTAIL
TERMINAL
Yellow
P1-1
Orange
P1-2
Black
P1-3
Red
P1-4
Drain
P1-5
Brown
P1-6
Blue
P1-7
Red/Green
P2-7
Tan
P2-6
Violet
P2-5
White
P2-4
Green
P2-3
Pink
P2-2
Gray
P2-1
Mounting holes for US double-gang electrical boxes.
DESCRIPTION
Beeper Input
LED Input (GRN)
Ground (RTN)
+VDC
Unused
LED Input (RED)
Hold Input
GPIO1/OSDP (RS485-FDX/HDX-A)
GPIO2/OSDP (RS485-FDX/HDX-B)
*Open Collector Output / Tamper
**Wiegand Data 1 / Clock
**Wiegand Data 0 / Data
GPIO3 (RS485-FDX-Z)
GPIO4 (RS485-FDX-Y)
2
PLT-03331, Rev. A.2
Notes
Previous iCLASS readers had
reversed RS-485 wiring (P2-7 &
P2-6 - A & B). When upgrading
to an iCLASS SE reader, ensure
proper connections as defined
below.
It is possible to reuse existing
Wiegand wiring for OSDP,
however, using simple stranded
cable typical of Wiegand
access control readers is
usually not meeting the RS485
twisted pair recommendations.
For OSDP cable lengths
greater than 200ft. (61M) or
EMF interference, install 120Ω
+/- 2Ω resistor across RS-485
termination ends.
Wiring the reader incorrectly
may permanently damage the
reader.