6. OPERATING DATA

6.1

ELECTRIC DATA

MK96R63DT
Currents
MK96R63MT
Reference current
Min. current
Max. current
V1,V2,V3,N voltages :
- 3x230V / 3x400V ±15%
V1,V2,V3,N rated frequency:
- F
: 50...60Hz
n
- Permitted variation : 45...65Hz
Self supplied :
- Rated frequency: 50/60Hz
- Operating frequency: 45...65Hz
- Self consumption: ≤ 2.5VA @230 Vac
Connectable section:
Terminals
Without bush
Rigid wire
0,05 ÷ 2,5 mm²
Flexible wire
0,05 ÷ 1,5 mm²
Necessary tools:
- For all the terminals, use a 2.5mm slotted screwdriver and/or a
PH0 screwdriver.

MECHANICAL DATA

6.2
Screw terminals:
- Max external dimensions: 18,5mm
- Lengths of the wire stripping: 6 / 7,5mm
Screw head:
- COMBI screws (slotted / Phillips head)
Recommended torque:
- For all the terminals: 0.5 Nm
Technical data sheet: IDP000264EN_05
MK96R125DT
MK96R125MT
10A
20A
0,5A
1A
63A
125A
With bush
0,05 ÷ 1,5 mm²
0,05 ÷ 1 mm²
Updated: 17/03/2021
Code: MK96R63DT – MK96R63MT
MK96R125DT – MK96R125MT
Model: NEMO 96 EC

7. GENERAL FEATURES

Front marking:
Indelible digital print.
Connection terminal board marking:
- by indelible tampography
CURRENT
A
B
1
C
INPUT
V
V
V
N
1
2
3
Display:
- Type: backlit liquid crystal display
- Reading points: 10,000 4 digits (digit height 12 mm)
- Energy measure: 8 digit meter (digit height 8 mm)
- Resolution: automatic
- Decimal point: automatic
- Update time: 1sec.
Display of the value and programming:
- By means of the front keypad, 4 pushbuttons
- Access protected by identification code
Measurements and precision in conformity with
- Current: cl.1
- Voltage: cl.0.5
- Frequency: ± 0.1 Hz
- Instantaneous total active power, phase, average value and max.
average value: cl.1
- Instantaneous total reactive power, phase, average value and max.
average value: cl.2
- Instantaneous total apparent power, phase, average value and
max. average value: cl.1
- Power Factor: cl.1
- Total active energy, positive and negative: cl.1
- Total reactive energy, positive and negative: cl.2
- Energia attiva tariffaria: cl.1
The above classes are guaranteed by maintaining the centring,
between Rogowski sensor and primary conductor, with the
appropriate accessories provided and a harmonic content within the
limits of the EN/IEC 61557-12 standard
Average power:
- Measurement: apparent, reactive, active power
- Calculation: moving average, on the selected period
- Average time: 5/8/10/15/20/30/60min.
Maximum dissipated thermal power for the thermal
dimensioning of the panels:
Created: 21/11/2019
(continues)
+
CURRENT
SG
INPUT
V
V
V
N
1
2
3
(see the user manual).
(predefined code 1000)
EN/IEC 61557-12
EN/IEC 62053-21
EN/IEC 62053-23
≤ 5W