3. Settings
TRANSMITTER RADSECTX
N° DIP
Function
1
DO NOT USE
Energy saving
2
OFF: disable / ON: enable
3
Selection frequency of
functioning
4
It is possible to associate up to a maximum of 4 transmitters (4 different edges) to each relay. For this reason, to each receiver can be associated a
maximum of 8 transmitters.
Warning: for a correct functioning of the system, every transmitter part must have the frequency dip put on the same way of the
correspondent receiver part.
In order to avoid any interferences on installations which need a higher number than 4 security channels it is advisable to distinguish the frequencies
utilized among the various receivers and their transmitters associated transmitters.
4. Connections
4.1 Connection RADSECTX transmitter
Connect the sensitive edge to the terminal boards of the transmitter
inserting the 8,2KΩ ¼ of Watt in series only in case clean contact
N.C. mechanical edge are utilized (see page 1).
1
Orientate and put the device as explained in figure.
If the 8,2KΩ ¼ of Watt is not connected (with mechanical edge)
the system does not work and enters in alarm.
Set the dip switch relative to the utilized frequency (dip 3 and dip 4)
2
which will have to correspond to the one of the receiver.
Give power to the system connecting the two batteries AA – 1,5 V to
3
the battery holder. Pay attention to the polarity .
Fix the device as much higher than possible in such a way as there
are no obstacles on the direction of the receiver and in such a way as
4
the maximum distance between the two devices is less than 15
meters. (max 20 meters).
4.2 Connection RADSECRX Receiver
Put the receiver in such a way to minimize the distance from the
transmitters associated and close the to the automation's control unit
1
or inside the box of the motor. If fixed to a wall, utilize suitable screws
and plugs so that it can resist to a force of 50N downwards.
Set the dip switch relative to the utilized frequency (dip 3 and dip 4)
2
which will have to correspond to the one of the transmitters.
Set the 2 little bridges Mec/8k2 (Jumper of selection output signal ) in
such a way as the state of functioning or of alarm is correctly
3
signaled, according to whether the control unit has an input of
mechanical type (with contact) or 8,2KΩ.
Set the little bridge of power supply
4
(24V o 12V)
Connect the test inputs to the control
5
unit, in case they are utilized (*).
The inputs are handled in the same way as the photocells test: the control unit, to carry out the photocells test, switches off the power supply of the
receiver and check that the relays of the correspondent receiver opens itself. In this device, the input TEST1 and TEST2 are for testing the security
devices (see chapter 12).
6-1620148 REV.2
25/10/2019
WARNING : ERREKA can not be considered responsible
for any damages caused by an improper use, incorrect
or irrational of the product.
WARNING: keep free the areas of access to the devices
and clean periodically them from eventual dirtiness
which can settle on them during the normal functioning.
ITA
ENG
FRA
ESP
DEU
POR
RECEIVER RADSECRX
N° DIP
Function
1
Test device
Buzzer
2
OFF: enable / ON: disable
3
Selection frequency of
functioning
4
MIN: 20 cm
9 / 28