Temperature Calibration; How To Use - Steren CAU-270 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Temperature calibration

You will need to calibrate the tip's temperature after tip or heating element replacement.
- Enter to calibration mode by long pressing *.
- Use ▲ or ▼ to adjust temperature.
- You have to use an external thermocouple to take tip's temperature.
- Select a preset temperature and pair the tip's temperature with the displayed one.
- The calibration range is +50 ~ -50 °C of the selected temperature.
- Press * to exit calibration mode.

How to use

If you use a wrong type of solder you could damage the device to be soldered.
1. Clean the surface where you'll make unions.
2. When the temperature stabilizes, apply new
solder to the tip.
3. Apply the solder using the tip on the connections
that you want to join. The solder will melt on the
object.
7

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido