Mounting And Installation - SSS Siedle SELM 600-0 Informacion De Producto

Lector de llaves electrónicas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
English
Application
Electronic key reading module with
MIFARE DESFire EV1/2 technology
as contactless access control system
with function LED. Compatible with
the new EK/EKC 600-... electronic
keys or cards.
Transponder
Compatible keys are:
• EK 600-... Electronic key
• EKC 600-... Electronic key card
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
Remarks
• If the Electronic key is attached to
a set of car keys, this can interfere
with your car immo-bilizer, as some
immobilizers work at the same fre-
quency. For this reason, we advise
not attaching your Electronic Key to
the same key ring as your car key.
• Magnetic fields can pose a
hazard for pacemakers, magnetic
data storage media and electronic
devices. A safe distance must be
maintained.
• The unit can be operated in the
following countries:
AT, BE, CH, DE, DK, ES, FI, FR, GB,
GR, IT, IS, NL, NO, PT, SE.
• Avoid direct sunlight/prolonged
exposure to heat. Observe the per-
missible temperature range.
Range
The conductor network laid
throughout the entire Vario bus
must not exceed 2000 m. The loop
resistance (forward and return line
between the functional unit and
the control unit) must not exceed
20 Ohm. A core diameter of 0.8 mm
results in a range of appr. 260 m.
The power supply to the Vario
Bus components is provided by a
6
separate transformer TR 602-.../
TR 603-...
Steps must be taken to ensure that
the supply voltage never exceeds
9 V AC at any device with maximum
current consumption.
1 Connection pcb
For surface mounted door stations:
Connection not via connection pcbs
but in a similar manner as Siedle
Vario using terminal blocks.
Terminal assignment
bv, cv
Power supply 12 V AC
Da, Db
Vario bus
S1, S2
n.o. contact 24 V, 2 A

Mounting and installation

2 Address setting
In order to change the Vario bus
address, the pre-mounted function
unit must be removed from the
mounting plate. See product infor-
mation for the door station.
3 Terminal plan for standalone
operation
4 Terminal diagram access control
with EC 602-...
5 Terminal diagram access control
with TCIP 603-...
Servicing
The functional unit can be com-
pletely exchanged if required.
Information regarding replacement
and checking the functional units
can be found in the product infor-
mation for the door station.
During stand-alone operation, all
keys must be re-read in after an
electronic key reading module is
replaced.
Specifications
Operating voltage: 12 V AC or
12–30 V DC
Operating current: max. 120 mA or
max. 50 mA
Contact type: contact 24 V, 2 A
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
Commissioning
Vario bus operation
During bus operation, the input/read
devices of the different access points
are linked to one another via a cen-
tral device (controller).
The key is read in during program-
ming via the EC 602-... or the
TCIP 603-...
Detailed information can be found in
the EC 602-... programming instruc-
tions or TCIP 603-... manual.
Stand alone operation
During stand-alone operation, each
input/read device is operated alone.
Used in stand-alone operation,
the ELM manages a maximum of
9 users (Electronic-Key EK and/
or Electronic-Key Card EKC) plus a
master card.
User keys EK/ user cards EKC must
be read in at the ELM units at which
they are required to trigger func-
tions. This reading process is initiated
and terminated with the master
card.
Procedure:
Reading in the master card
After completion of installation and
switching on the system, a red LED
lights up at the front of the ELM.
The ELM is ready for the reading
process. The first user card EK/EKC
read into the ELM is automatically
defined as the master card, and can
be used to terminate the reading
process at any time or to restart a
new reading process. Make sure
that the master card is kept in a safe
place after completion of program-
ming.
• Hold the EK/EKC up to the ELM.
The master card has been success-
fully read in. The ELM is automati-
cally switched to the service mode.
This is signalled by a green LED.

Publicidad

Tabla de contenido
loading

Tabla de contenido