Broan 678 Manual De Instrucciones
Ocultar thumbs Ver también para 678:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

FAN/LIGHT
COMBINATION
VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from be-
ing switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heat-
ing, Refrigeration and Air Conditioning Engineers (ASHRAE), and
the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
TYPICAL INSTALLATIONS
POWER CABLE
CEILING
JOIST
CEILING
MATERIAL
16"-ON-CENTER
CEILING JOISTS
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
2678F, 2679F, 2680F, FL2679F
& FL2680F FINISH PACKS
3677H HOUSING PACK
MOUNTING
BRACKETS
HOUSING
GRILLE
MODELS 678 • 679 • 680 • 679FL • 680FL
FOR USE WITH
WARNING
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or shower.
9. Fluorescent models only: Do not use a dimmer switch to control
the light of this unit.
10. This unit must be grounded
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. This product is designed for ceiling installation only. This product
is designed for installation in ceilings up to a 12/12 pitch. Ductwork
must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impel-
lers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and
requirements.
CEILING
JOIST
CEILING
MATERIAL
.
!
POWER CABLE
HOUSING
For a rigid mount: Brackets can
be joined together with a
GRILLE
#8 x 3/8 self-tapping screw
24"-ON-CENTER
CEILING JOISTS
Page 1
MOUNTING
BRACKETS

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan 678

  • Página 1 MODELS 678 • 679 • 680 • 679FL • 680FL FAN/LIGHT Page 1 2678F, 2679F, 2680F, FL2679F COMBINATION & FL2680F FINISH PACKS FOR USE WITH VENTILATORS 3677H HOUSING PACK READ AND SAVE THESE INSTRUCTIONS WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 6.
  • Página 2 MODELS 678 • 679 • 680 • 679FL • 680FL Page 2 INSTALL THE HOUSING INSTALL THE HOUSING (continued) New Construction New Construction 1. Slide adjustable mounting brackets into channels on sides of housing. 2. Choose the location for your fan/light in the ceiling.
  • Página 3: Connect The Wiring

    MODELS 678 • 679 • 680 • 679FL • 680FL Page 3 INSTALL THE HOUSING CONNECT THE WIRING (continued) SCHEMATIC WIRING DIAGRAM L I G H T R E D B L U L I G H T Existing Construction...
  • Página 4: Service Parts

    This warranty supersedes all prior warranties. replace- 97014185 Damper/Duct Connector To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or 98008868 Wiring Plate ment parts telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part.
  • Página 5: Instalaciones Típicas

    MODELOS MODELS 678 • 679 • 680 • 679FL • 680FL Página 5 Page 5 VENTILADORES PAQUETES TERMINAR 2678F, 2679F, 2680F, FL2679F, & FL2680F CON LÁMPARA POR USO CON 3677H PAQUETE DE CAJA LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA ADVERTENCIA 6.
  • Página 6: Instalación De La Cubierta

    MODELOS MODELS 678 • 679 • 680 • 679FL • 680FL Página 6 Page 6 INSTALACIÓN DE LA CUBIERTA INSTALACIÓN DE LA Construcción nueva CUBIERTA (continuación) 1. Resbale los soportes de Construcción nueva montaje ajustables dentro de los canales en caras de la caja.
  • Página 7: Conexión Eléctrica