Connecting The Power; Connecting To The Cmc; Configuring The Cmc; Connecting The Cmc To Your Network - Riverbed Steelhead CX Guía Rápida De Instalación

Tabla de contenido

Publicidad

Installing the Central Management Console

3. Connecting the Power

If your model has a master power switch, make sure it is in the off position (on the rear panel).
Plug the power cord or cords into the CMC and an AC outlet.
If your model has a master power switch, press in the master power switch (ON).
Press in the system power switch on the front of the CMC.
Caution: In all European electrical environments, you must ground the Green/Yellow tab on the power cord. If you do
not ground the Green/Yellow tab, it can cause electrical shock.

4. Connecting to the CMC

Plug the serial cable into the Console port and a terminal.
Make sure the Console port settings are: 9600, 8 data bits, no parity, 1 stop bit, no flow control.
Start your terminal emulation program (for example, HyperTerminal or Tera Term Pro).
At the login prompt, type admin. The default password is password.

5. Configuring the CMC

The configuration wizard automatically starts when you log into the command-line interface for the
first time.
Follow the prompts to configure network and in-path interface settings for the CMC.
Confirm your settings; then type exit to log out of the system.

6. Connecting the CMC to Your Network

Make sure you use the correct cables to connect to your network:
Straight-through cables: Primary and LAN ports to LAN switch.
112
Installing the CMC
Getting Started Guide

Publicidad

Tabla de contenido
loading

Tabla de contenido