Direct Current Measurement; Alternating Current Measurement - Würth MM 600 TRMS Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
Device elements (Fig. I)
No. Description
1
Display
2
Light button
3
Hold measure-
H
ment button
4
ON/OFF switch
(via rotary
switch)
4
Selector switch
Measuring
function
5
Common (earth)
socket
6
Input socket
(right)
7
10 A socket
(left)
8
M
Mode button
Function
Measurements and
settings are dis-
played.
Pressing switches the
torch function on and
off.
Pressing the button
holds the currently
displayed measured
value.
The device is switched
on by selecting a
measuring range
and then switched
OFF
off again in the
position.
The various basic
measuring types can
be selected by turning
the rotary switch.
Black measuring lead
for all signal types
permitted for the
device.
Red measuring lead
for all signal types
permitted for the
device.
For measurements
above 250 mA, the
10 A socket must be
used.
Pressing switches the
device to another
mode.
Operation

Direct current measurement

Set the selector switch [4] to measurement range
V
. Connect the black measuring lead to the
COM socket [5] and the red measuring lead to the
right socket. Connect the measuring leads to the test
object. The multimeter automatically searches for
the most favourable measurement range. Read the
measurement result from the display [1].
DC voltage
Measuring
Resolution Accuracy
range
200 mV
0.1 mV
2 V
0.001 V
20 V
0.01 V
200 V
0.1 V
600 V
1 V
Input resistance: 10 MΩ.
Max. input voltage: 600 V DC.

Alternating current measurement

Set the selector switch [4] to V~.
Connect the black measuring lead to the COM
socket [5] and the red measuring lead to the
right socket.
Connect the measuring leads to the test object.
The multimeter automatically searches for the
most favourable measurement range. Read the
measurement result from the display [1].
AC voltage
Measuring
Resolution Accuracy
range
200 mV
1 mV
2 V
0.001 V
20 V
0.01 V
200 V
0.1 V
600 V
1 V
Input resistance: 10 MΩ.
Max. input voltage: 600 V AC RMS,
frequency range: 40-400 Hz.
± 0.5 % of the
measured value +
3 digits
± 0.8 % of the
measured value +
3 digits
± 1.5 % of the
measured value +
5 digits
15