Before commissioning
After unpacking the device and before starting it, make sure there is no damage and that
your order is complete:
•
Air Quality monitor x 1
•
Micro-USB charging cable x 1
•
Product Manual x 1
Commissioning
1. Start Up
Buttons:
To turn on the air quality monitor, press the power button. To turn it off, press the power
button for 3 seconds.
Use the right/left buttons to adjust the time and date as mentioned below.
Calibration:
After turning on the device for the first time, place it outside in a place where there is
good air ventilation. After 5-10 minutes, press and hold the left button for 3 seconds (until
you hear the signal). The HCHO/TVOC calibration is complete.
Time setting:
When the device is turned on, quickly press the power button 3 times to enter the time
setting mode.
•
Use the Right/Left buttons to adjust the hours.
•
Click on the Power button to switch to minutes, and use the Right/Left buttons to
adjust the minutes.
•
Click on the Power button to switch to seconds, and use the Right/Left buttons to
adjust the seconds.
•
When the adjustments are finalised, press the power button to confirm and
complete the time setting.
2. Displayed air parameters
Carbon Dioxide (CO2) indicator
•
Measuring range: 400 – 5000 PPM
•
Sensor technology: Infrared (NDIR)
•
Resolution: 1 PPM
PM2.5 / PM10 indicator
•
Measuring range: 0 – 999ug/m3
6