Led Lights & Buttons On Ceiling Assembly - RV Products AIRXCEL Coleman-Mach 47000 Serie Instrucciones Operativas Y De Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Press the PROGRAM button to select the set point temperature for Cooling. Press the UP or DOWN
button to select the desired temperature.
Press the PROGRAM button to select the set point temperature for Heating. Press the UP or DOWN
button to select the desired temperature.
Press the PROGRAM button to select the set point temperature for Auto. Press the UP or DOWN button to
select the desired temperature.
Repeat this procedure to select the start times and set point temperatures for Monday Day, Monday Evening
and Monday Night.
Repeat this procedure for the remaining days of the week.
If the unit is in the COOL, HEAT, or AUTO mode, it can be run in either the Manual Run mode or the
7-Day Preprogrammed Run mode. Pushing the PROGRAM button will toggle between the Manual Run
mode and 7- Day Preprogrammed Run mode. While in the 7-Day Preprogrammed Run mode, PROGRAM
will appear at the bottom of the screen. The set point temperatures maybe changed by pushing the UP &
DOWN buttons. The manually set temperature will remain in effect until the start of the next
preprogrammed period. The 7-Day preprogrammed mode is not available in the Fan only or Dry mode.
XI. LED lights and buttons on the ceiling assembly.
The ceiling assembly has a two color LED to indicate if the unit is in Cooling or Heating. Two manual
override buttons - one for cooling the other for heating – can be used if the remote controller is lost or
malfunctions.
Infrared receiver
Two color LED
-7-
Red for Heating
Blue for Cooling
Manual override buttons
for Heating & Cooling