Configuration Parameters - Ariston 3024173 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

start-up
Warning
To ensure the safety and correct opera-
tion of the module, it must be started up
by a legally qualifi ed and authorised tech-
nician.
Ignition procedure
- Power up the module.
- Remove the cover of the control unit con-
nection shoe (see electrical diagram).
- Insert the system interface into the con-
nection shoe by pushing it gently down-
wards; after a brief initialisation, the sys-
tem interface will be connected.
- The display will show Error 214 "hydraulic
circuit diagram not defi ned".
- Simultaneously press the back "
"OK" buttons until "Enter code" appears
on the display.
- Turn the knob to enter the technical code
(234) then press OK; the display will show
TECHNICAL AREA:
- Language, date and time
- Bridge Net Bus settings
- Guided confi guration
- Maintenance
- Errors
- Complete menu
In order to facilitate the solar parameter
setting operations without accessing the
complete Menu, confi guration can be per-
formed through the rapid access menu:
- Bridge Net Bus settings.
Turn the knob and select:
- BRIDGE NET BUS SETTINGS
Press the OK button.
The display will show the list of devices
present in the system:
- System interface (local)
- Solar control
- ...
- Confi rm components
The confi gurable devices are marked by the
"
" symbol.
To select the hydraulic circuit diagram and
type of pump unit, turn the knob and select:
- Solar control
Press the OK button.
Turn the knob and select the type of indi-
rect cylinder used, from the following:
-
-
Press the OK button.
- Type of pump assembly
Turn the knob and select:
- Analogue
The display will show the type of hydraulic
" and
circuit diagram used.
Press OK to confi rm the choice, or press
the back button "
ous screen.
To confi gure the peripherals, turn the knob
and select
- GUIDED CONFIGURATION:
Press the OK button.
Turn the knob and select:
- Solar control
Press the OK button.
Turn the knob and select from the follow-
ing:
- Parameters
- Test mode
- Guided procedures
Turn the knob and select:

- CONFIGURATION PARAMETERS

(allows the display and setting of essential
parameters for correct system operation)
Press the OK button.
- Solar confi guration
Press the OK button.
Turn the knob and select:
- 3 2 0 Thermal Disinfection function
Turn the knob to set the thermal disinfec-
tion function:
0 OFF
1 ON
-
" to return to the previ-
GB
19

Publicidad

Tabla de contenido
loading

Tabla de contenido