2. OUTPUT
Voltage
*Max load
Min load
Peak load
*Combined power
*Regulation
*Ripple & Noise
*The continuous total output power is 500W max.
。The combined power of +5V and +3.3V is 100W max.
。 Peak currents may last up to 12 seconds with not more than one occurrence per minute.
* Add 0.1uF and 10uF capacitors across output terminal during ripple & noise test.
* Cross load setting table
LOAD1
LOAD2
LOAD3
LOAD4
LOAD5
2.1 REMOTE ON/OFF
Disable
Enable
+5V
+3.3V
15.0A
15.0A
2.0A
2.0A
--
--
100W
+5,-5%
+5,-5%
50mV
50mV
+5V
+3.3V
3A
38A
15A
7.6A
3A
7.6A
3A
7.6A
3A
7.6A
Hysteresis
_
0.8V
PS it
enabled
0.8V
PS/ON # Voltage
+12V
-12V
38.0A
0.3A
6.64A
0.05A
--
--
--
--
+5,-5%
+10,-10%
120mV
120mV
+12V
-12V
3A
0A
3A
0A
15A
0A
3A
0.3A
3A
0A
> _
0.3V
> _
2.0V
PS it
disabled
2.0V
+5Vsb
2.5A
0.4A
--
--
+5,-5%
50mV
+5Vsb
0.4A
0.4A
0.4A
0.4A
2.5A
5.25=Maximum
Open-circuit Voltage