3.0 PROTECTION
When OVP ,OPP or short protection is triggered, the main outputs will be latched off. The main outputs can be
reset by cycling the DC remote on/off or AC power. +5Vsb output is auto recovery when fault condition removed.
3.1 OVER VOLTAGE PROTECTION
+3.3V output
3.84 Vmax.
+5.0V output
7.0 Vmax.
+12.0V output 14.2 Vmax.
3.2 SHORT Current PROTECTION
All output to GND.
3.3 OVER POWER PROTECTION
Foldback at 110%~150% over peak load
4.0 TIME SEQ.TEST
+12V, +5V, +3.3V OVP
PW-OK
PW-OK Sense
Level=95% of Nominal
4.1 Start Time:T1≦500ms
4.2 +12V、+5V、+3.3V voltage Rise time:0.1ms≦T2≦20ms
4.3 PG delay time:100ms<T3<500ms
4.4 PG rise time:T5≦10ms
4.5 AC power failure protection time:T6≧10ms/70% Load
4.6 PF delay time:T4≧1ms
Vac
ON
PS/ON
OFF
95%
10%
T1
T3
T2
T5
T6
T4