NOTE: If one wing reaches a stop and button P1 is not pressed, then the motor moves towards the stop and stores this position
automatically.
COMPLETION OF INSTALLATION / PROGRAMMING
Once the travel distances are programmed, the remote controls can be programmed as well.
(Refer to PROGRAMM / DELETE REMOTE CONTROLS).
1.
You can now let the door run 2 complete cycles by pressing a key on the remote or a connected switch and observe the
process. Close the door again, WITHOUT making another setting.
2.
If all adjustments are done, check operation of photocells, switch, flashing light, remotes, accessories, etc.
3.
Advise people using the gate with regard to gate operation, safety functions and how to release the gate in
order to operate it manually.
TIMER TO CLOSE (AUTO-CLOSE)
NOTE: Only possible with connected photocells (1 + COM). Time frames from 2 seconds up to 120 seconds are possible.
Activate:
1.
Press and hold P2 until yellow LED starts flashing
2.
Now count the time you wish to program
3.
Press P2 again. Done!
Deactivate:
1.
Press and hold P2 until yellow LED starts flashing.
2.
Press P3. Yellow LED goes out. Done!
FORCE / TORQUE OF MOTOR
Thrust of the motor is set automatically while programming
the travel distance. Thrust can only be modified by
programming the travel distance again. If gate movement is
impeded by weather or changes to the installation (rust or
inappropriate lubrication) it may have to be repaired.
BATTERY DISPOSAL
Batteries and rechargeable batteries may not be disposed along with domestic waste, but are
obliged to be returned.
After use they can be returned free of charge locally e.g. in trade or at municipal collecting
points.
Batteries and rechargeable batteries are marked with a crossed waste container as well as
with the chemical symbol which describes their toxic element, "Cd" for cadmium, "Hg" for
mercury and "Pb" for lead.
The control board complies with the latest EU guidelines.
One of these guidelines specifies that the closing forces
at the gate edge must not exceed 400N (40 kg) for the last 500 mm
before the door is CLOSED. Above 500 mm, the maximum force at
the gate edge must not exceed 1400 N (140 kg). If this cannot be
ensured, a contact strip must be mounted on the gate at a height up
to 2.5 m or on the pillar on the opposite side (EN12453).
Pb
Cd
Hg