Fault
Compressor runs
without building up
sufficient pressure.
Air tool does not
receive enough
pressure.

Maintenance / care

Before any work on the device:
Switch off the device and unplug.
¾
Wait until the device is at a standstill.
¾
Ensure that the device and all air
¾
tools and accessory parts are depres-
surised.
Allow the device and all air tools and
¾
accessory parts to cool.
After any work on the device:
Start up and check all safety devices.
¾
Ensure that there are no tools or
¾
similar on or in the device.
Advanced maintenance and
¾
repair work as described in this
chapter, must only be carried out by
specialists.
Note
Maintenance and inspections must be
planned and performed according to
the legal regulations dependent on
the set-up and operating mode of the
device.
Supervisory authorities can request the
submission of corresponding documen-
tation.
24
Possible cause
Condensate drain leaking.
Non-return valve leaking.
Pressure controller not turned
up high enough.
Hose connectors between com-
pressor and air tool are leaky.
DANGER!
Remedy
Ensure that the condensate drain [7] is closed.
Check the seal of the drain plug, replace as necessary
The non-return valve must be repaired by a specialist
workshop.
Turn pressure controller [15] up higher.
Check the hose connectors, replace damaged parts as
necessary.
Attention!
Check the tightening torques of the cylinder head
bolts on the compressor [12] after the first 50 and
250 operating hours (see technical data).

Before each use

Inspect air hoses for damage, replace as neces-
sary.
Check screw connections are tightly seated,
tighten as necessary.
Check the supply cable for damage; if necessary
arrange replacement by an electrician.
Check the oil level of the compressed air
oiler [19], top up with pneumatic oil as neces-
sary.
Daily
Drain the pressure tank condensation at the
condensate drain [7].

Every 50 operating hours

Clean the air filter [13] (Fig. VII).
Check the compressor oil level at the oil sight
glass [10], replenish the oil as necessary.
Drain the condensation water at the filter pressure
reducer [20].
Clean or replace the air filter in the filter pressure
reducer (Fig. VIII).
Unscrew the belt guard [1] and check the V-belt,
if necessary retighten or replace (Fig. IX).
— To adjust the belt tension, loosen the four screws
at the base of the motor and move the motor.
— Retighten the screws at the base of the motor.
— Refit the belt guard.